首页|期刊导航|电力系统保护与控制|考虑光伏电流相位影响的配电网电流保护适应性边界研究

考虑光伏电流相位影响的配电网电流保护适应性边界研究OA

Research on current protection adaptability boundary in distribution networks considering the influence of photovoltaic current phase angle

中文摘要英文摘要

新能源接入改变了新型电力系统故障特征,导致传统继电保护适应性下降.针对现有分布式电源保护适应性边界研究中隐含光伏故障电流与系统侧电流同相位假设导致边界失准的问题,提出一种基于相量分析的保护适应性量化方法.首先,建立计及低电压穿越控制的光伏电源故障模型,分析其故障特性.进而,通过理论推导与相量分析,深入研究光伏接入在助增与外汲两种场景下对保护安装处故障电流幅值与相位的影响机制.在此基础上,量化分析了助增场景下保护Ⅰ段失配、外汲场景下保护范围缩减的临界条件.结果表明,在典型10 kV配电网参数下,当光伏容量低于系统最大短路容量的 16%时,可避免因光伏助增导致的保护失配.同时,推导了外汲作用下保护范围缩减程度的解析表达式.所推导的保护适应性边界可为保护风险评估与定值校核提供理论依据.

The integration of renewable energy has changed the fault characteristics of new power systems,leading to degradation of adaptability of traditional relay protection.Existing studies on protection adaptability boundaries of distributed generation implicitly assume that photovoltaic(PV)fault currents are in phase with the system-side currents,resulting in boundary inaccuracies.To address this issue,a quantitative method for protection adaptability based on phasor analysis is proposed.First,a PV generation fault model considering low-voltage ride-through(LVRT)control is established,and its fault characteristics are analyzed.Then,through theoretical derivation and phasor analysis,the influence mechanisms of PV integration on the magnitude and phase of the fault currents at the relay location under two typical infeed and outfeed scenarios are thoroughly investigated.On this basis,the critical conditions for Zone I protection mismatch under the infeed scenario and protection range reduction under the outfeed scenario are quantitatively derived.The results indicate that,under typical 10 kV distribution network parameters,protection mismatch due to PV infeed can be avoided when the PV capacity falls below 16%of the maximum system short-circuit capacity.Furthermore,an analytical expression for the degree of protection range reduction under the outfeed effect is derived.The derived protection adaptability boundaries provide a theoretical foundation for protection risk assessment and setting verification.

李猛;刘蓓蓓;王昊月;杜晓通;王语然;和敬涵

北京交通大学电气工程学院,北京 100044北京交通大学电气工程学院,北京 100044北京交通大学电气工程学院,北京 100044北京交通大学电气工程学院,北京 100044北京交通大学电气工程学院,北京 100044北京交通大学电气工程学院,北京 100044

光伏配电网故障特性保护适应性边界条件

photovoltaicdistribution networkfault characteristicprotection adaptabilityboundary condition

《电力系统保护与控制》 2026 (20)

97-106,10

This work is supported by the National Science and Technology Major Project for Smart Grid(No.2024ZD0800804). 智能电网国家科技重大专项(2030)资助(2024ZD0800804)国家电网有限公司总部科技项目资助(SGTJDK00DWJS2400298)"低碳高可靠城市配电系统示范工程"

10.19783/j.cnki.pspc.260254

评论