计及构网型控制的高比例分布式电源配电网短路电流计算OA
Short-circuit current calculation for distribution networks with high penetration of distributed generation considering grid-forming control
目前,针对含跟网型分布式电源(distributed generation,DG)的配电网短路电流计算,普遍采用不动点迭代法进行求解.然而,随着 DG 容量增大以及渗透率增加,不动点迭代法的收敛性能变差.构网型 DG 接入后,会进一步增强短路电流计算的非线性特征,导致不动点迭代法收敛性能的进一步恶化.为此,提出了一种基于拟牛顿秩 2 方法的含 DG 配电网短路电流计算的新型迭代方法.首先,分析了构网型分布式电源接入对传统不动点迭代法收敛性能的影响.其次,结合具有较好收敛性能和收敛鲁棒性的拟牛顿秩2方法——Broyden-Fletcher-Shanno(B-F-S)方法,阐述了其基本原理,并给出了 B-F-S 方法在含 DG 短路电流计算中的具体应用步骤.然后,分析了构网型DG 接入对于拟牛顿法数值稳定性的影响.最后,在 IEEE43 节点网络中验证了算法准确性.并以 IEEE300 节点电网为例,通过与现有方法进行对比分析,验证了所提算法具有更好的收敛性能以及收敛鲁棒性.
The fixed-point iteration method is widely adopted for short-circuit current calculation in distribution networks integrated with grid-following distributed generation(DG).However,with the increasing DG capacity and penetration level,the convergence performance of the fixed-point iteration method deteriorates.The integration of grid-forming DG further intensifies the nonlinear characteristics of short-circuit current calculation,further degrading the convergence performance of the fixed-point iteration method.To address this challenge,a novel iterative method based on the quasi-Newton rank-two method is proposed for short-circuit current calculation in distribution networks with DG.First,the impact of grid-forming DG integration on the convergence performance of the conventional fixed-point iteration method is analyzed.Second,the Broyden-Fletcher-Shanno(B-F-S)method,a quasi-Newton rank-two method with good convergence performance and convergence robustness,is introduced.The basic principle of the B-F-S method is presented,and its implementation procedure for short-circuit current calculation with DG is provided.Furthermore,the influence of grid-forming DG integration on the numerical stability of the quasi-Newton method is investigated.Finally,the accuracy of the proposed algorithm is validated on the IEEE43-bus distribution network,and comparative analysis against existing methods on the IEEE300-bus power system demonstrates its improved convergence performance and robustness.
宋子佳;李海锋;王玕;吴争荣;梁远升;王钢
华南理工大学电力学院,广东 广州 510640华南理工大学电力学院,广东 广州 510640华南理工大学电力学院,广东 广州 510640南方电网科学研究院有限责任公司,广东 广州 510663华南理工大学电力学院,广东 广州 510640华南理工大学电力学院,广东 广州 510640
构网型分布式电源短路电流计算不动点迭代法拟牛顿法收敛特性
grid-forming distributed generationshort-circuit current calculationfixed-point iteration methodquasi-Newton methodconvergence characteristics
《电力系统保护与控制》 2026 (20)
1-12,12
This work is supported by the Natural Science Foundation of Guangdong Province(No.2024A1515012289). 广东省自然科学基金项目资助(2024A1515012289)
评论