为满足钢-混凝土组合模块建筑的工厂智能化生产、现场工业化施工需求,提出了带端柱的钢-混凝土组合剪力墙,该类剪力墙水平方向采用交替布置的轻钢桁架与分布钢筋,竖向采用分布钢筋,端部以钢管混凝土作为边缘构件,并通过芯柱灌浆节点连接上、下层钢管混凝土端柱.为研究这种组合剪力墙的抗震性能,设计了 6个剪力墙进行低周往复加载试验,设计参数包括轴压比(0.3、0.6)、剪跨比(1.5和2.0)、混凝土强度等级(C40、C60).结果表明:剪力墙发生压弯破坏,破坏过程及破坏模式与传统带钢管混凝土边缘构件的剪力墙相近,芯柱灌浆节点未发生破坏;水平轻钢桁架与混凝土可协同变形,桁架能充分参与剪切受力;所有剪力墙的极限位移角均超过1/90,满足对于剪力墙的变形能力要求;当位移角小于1/800时,墙底截面的应变沿截面高度近似线性分布,基本符合平截面假定规律,随着荷载的增加,各测点应变呈非线性分布.在试验参数范围内提出了正截面承载力计算方法,承载力计算值与试验值吻合良好.

To meet the demands of intelligent factory production and on-site industrialized construction for steel-concrete composite modular buildings,this paper proposes a steel-concrete composite shear wall with boundary columns.Light steel trusses and distributed reinforcement are arranged alternately along the horizontal direction of the shear wall,while distributed reinforcement is adopted vertically.Concrete-filled steel tubes(CFSTs)serve as boundary elements at the wall ends,and the upper and lower layers of CFST boundary columns are connected via grouted core column joints.To investigate the seismic performance of this composite shear wall,six specimens were designed and tested under cyclic reversed lateral loading.The design parameters include axial compression ratios(0.3,0.6),shear span ratios(1.5,2.0),and concrete strength grades(C40,C60).The test results indicate that all shear wall specimens fail in flexural-compression mode,with failure processes and patterns similar to conventional shear walls with CFST boundary elements;no damage is observed in the grouted core column joints.The horizontal light steel trusses and concrete exhibit compatible deformation,and the trusses fully contribute to shear resistance.The ultimate drift ratio of all shear wall specimens exceeds 1/90,satisfying the deformation capacity requirements for shear walls.Before the drift ratio reached 1/800,strains at the wall base cross-section are approximately linearly distributed along the section depth,basically conforming to the plane section assumption.As the load increased,the strain distribution at each measuring point become nonlinear.Within the scope of the test parameters adopted in this study,a calculation method for flexural ultimate capacity was proposed,and the calculated ultimate capacities agreed well with the experimental results.

宋佳;于春义;田春雨;王文静;李新伟;张勇波;邓杨鹏

中建科技集团有限公司,北京 100070||绿色建筑全国重点实验室,陕西西安 710055中建科技集团有限公司,北京 100070||绿色建筑全国重点实验室,陕西西安 710055中建科技集团有限公司,北京 100070||绿色建筑全国重点实验室,陕西西安 710055中建科技集团有限公司,北京 100070||绿色建筑全国重点实验室,陕西西安 710055中建科技集团有限公司,北京 100070||绿色建筑全国重点实验室,陕西西安 710055中建工程试验检测(北京)有限公司,北京 101300中建工程试验检测(北京)有限公司,北京 101300

建筑与水利

模块建筑组合剪力墙钢管混凝土端柱拟静力试验抗震性能

modular buildingcomposite shear wallconcrete-filled steel tube end columnquasi-static testseismic performance