钢绞线-钢筋混合配筋钢纤维混凝土柱抗震性能OA
Seismic performance of steel fiber reinforced concrete columns with hybrid steel strands and steel bars
钢筋混凝土柱在强震作用后通常产生较大塑性变形与严重局部损伤,为提高混凝土柱恢复性能,设计了 6根不同钢绞线替代位置、钢绞线替代率和轴压比的钢绞线-钢筋混合配筋钢纤维混凝土柱,并进行低周往复荷载试验.结果表明:柱均发生典型的弯曲破坏,具有明显的屈服特征;钢绞线替代率由0%增加至100%,柱峰值荷载、峰值位移角、极限位移角和累积耗能分别提高16.85%、217.98%、111.73%和198.22%,残余位移角、最大裂缝宽度和残余裂缝宽度分别降低77.17%、33.22%和83.86%;由钢绞线替代角部纵筋时,相对替代侧边中部纵筋,柱峰值位移角提高17.41%~33.44%,但累积耗能降低11.26%~32.44%;轴压比由0.15增加至0.2,柱峰值荷载和侧向刚度分别提高6.23%~13.65%和8.59%~19.26%,但累积耗能降低7.56%~13.26%,残余位移角增大9.51%~41.58%.同时,进一步提出了钢绞线-钢筋混合配筋钢纤维混凝土柱峰值荷载计算方法,最大误差为6.13%,平均误差为3.02%.
Reinforced concrete columns usually exhibit significant plastic deformation and severe local damage after strong earthquakes.To enhance the resilience of concrete columns,six steel fiber reinforced concrete columns with hybrid steel strands and steel bars(SSFRC)with different steel strand replacement positions,replacement ratios and axial compression ratios were designed for low-cycle reversed loading tests.The results show that all columns experience typical flexural failure with distinct yield characteristics.As the steel strand replacement ratio increases from 0%to 100%,the peak load,peak drift ratio,ultimate drift ratio,and cumulative energy dissipation of the columns increase by 16.85%,217.98%,111.73%and 198.22%,respectively,while the residual drift ratio,maximum crack width and residual crack width decrease by 77.17%,33.22%and 83.86%,respectively.When steel strands replace the corner longitudinal bars,compared to the replacement of the middle longitudinal bars on the side,the peak drift ratio of columns increases by 17.41%-33.44%,but cumulative energy dissipation decreases by 11.26%-32.44%.As the axial compression ratio increases from 0.15 to 0.2,the peak load and lateral stiffness of columns increase by 6.23%-13.65%and 8.59%-19.26%,respectively,but cumulative energy dissipation decreases by 7.56%-13.26%,and the residual drift ratio increases by 9.51%-41.58%.A calculation method for the peak load of SSFRCs was proposed,with the maximum and average errors of 6.13%and 3.02%,respectively.
赵军;陈哲涵;李小鹏;刘雪峰;曾令昕
郑州大学土木工程学院,河南郑州 450001||河南省建筑安全与防灾减灾国际联合实验室,河南郑州 450001郑州大学土木工程学院,河南郑州 450001||河南省建筑安全与防灾减灾国际联合实验室,河南郑州 450001郑州大学土木工程学院,河南郑州 450001||河南省建筑安全与防灾减灾国际联合实验室,河南郑州 450001郑州大学土木工程学院,河南郑州 450001||河南省建筑安全与防灾减灾国际联合实验室,河南郑州 450001华北水利水电大学土木与交通学院,河南郑州 450045
建筑与水利
钢绞线钢纤维混凝土抗震性能恢复性能轴压比
steel strandsteel fiber reinforced concreteseismic performancerecovery performanceaxial compression ratio
《建筑结构学报》 2026 (9)
29-43,15
国家自然科学基金项目(52408306),国家重点研发计划(2016YFE0125600),河南省青年人才托举工程(2026HYTP003),教育部创新团队发展计划(IRT_16R67).
评论