基于线圈互感的大型磁屏蔽装置消磁能量耦合规律与调制方法OA
Investigation of Demagnetization Energy Coupling Regularity and Modulation Methods Based on Coil Mutual Inductance for Large-Scale Magnetic Shields
大型磁屏蔽装置是支撑生物磁成像、基础物理等前沿科学探索的重要基础设施,当前该类装置普遍利用多个磁屏蔽层构建高性能近零磁环境.大型磁屏蔽装置设计复杂、造价昂贵,为满足不同实验剩磁环境需求,该文研究一种多区布置的磁屏蔽装置,其可在单个磁屏蔽装置内,于各分区构建差异化的剩磁分布.然而,这类结构在消磁过程中面临显著的区际耦合干扰:某一区域消磁线圈产生的时变磁场,会在其他区域感应出附加电动势,扰乱预设电流与磁场分布,严重影响极弱磁环境下的剩磁控制精度.针对上述问题,总结得到一种基于消磁线圈互感与屏蔽材料非线性磁导特性的耦合分析方法.通过建立材料非线性磁化模型,构建两区互感耦合理论,核验不同电压幅值与频率下的感应电动势,进而分析互感系数变化规律.分区消磁实验结果表明,区域剩磁变化趋势与互感系数高度一致.在剩磁低于 5 nT 的 2 m 直径磁屏蔽区中,互感与剩磁呈现显著相关性(R2=0.994),通过频率优化可使该区剩磁降低约 85%.由此可见,在极弱磁条件下消磁线圈间的互感耦合是决定剩磁水平的关键因素.
Large magnetic shielding devices are crucial infrastructure supporting cutting-edge scientific explorations in biomagnetic imaging and fundamental physics.This paper studied a multi-zone magnetic shielding device.By dividing different shielding areas within a single device,a differential residual magnetic distribution was constructed to meet different research fields.Meanwhile,the total material consumption was reduced to optimize costs.As a scaled-down prototype of a large magnetic shielding device,this device adopts an"outer zone-inner zone"partition design.The outer zone has a relatively large area and is equipped with two shielding layers,which is suitable for fundamental physics exploration and pre-testing of weak-magnetic equipment;the inner zone(core zone)has two additional shielding layers based on the outer-zone shielding,which can support cutting-edge research that is extremely sensitive to magnetic fields,such as zero-magnetic medicine,neuroscience,and inertial measurement in extremely weak magnetic fields. During the independent degaussing process of each zone,the device faces significant inter-zone coupling interference.The time-varying magnetic field generated by the degaussing coil in one zone can induce an additional electromotive force in other zones,disturbing the preset current and magnetic field distribution and affecting the control accuracy of the residual magnetic field in an extremely weak magnetic environment.Therefore,this paper proposed a coupling analysis method based on the mutual inductance of coils and the nonlinear magnetic permeability characteristics of materials. The coils were wound around the shielding layer,and air served as the magnetic flux coupling path.Amutual-inductance coupling model of the two-zone degaussing coils was established.Based on the magnetic permeability characteristics of the shielding layer,a two-zone mutual-inductance coupling theory was constructed,and the induced electromotive force under different voltage amplitudes and frequencies was verified.Then,the mutual-inductance coefficients under various excitation conditions were calculated.Variations in the mutual-inductance coefficients were consistent with the theoretical analysis.When the voltage amplitude was the independent variable,the mutual inductance of the two-zone coils first increased and then decreased,with maximum differences of 2.89 μH(when the excitation was 5 m)and 12.26 μH(when the excitation was 2 m).When the frequency was the independent variable,the mutual-inductance coefficient increased monotonically under the 5 m excitation.It first increased and then decreased under the 2 m excitation,with maximum differences of 7.29 μH(when the excitation was 5 m)and 15.59 μH(when the excitation was 2 m).Subsequently,a partition degaussing experiment was carried out with the voltage amplitude and frequency as independent variables,and the extreme and average values of the residual magnetic field at multiple points in the two zones were measured. The results indicate that variations in the residual magnetic field closely align with changes in the mutual inductance coefficient.Within the tested parameter range—frequency from 10 Hz to 30 Hz,degaussing voltage of 25 V to 250 V for the 5 m zone,and 10 V to 40 V for the 2 m zone—a larger mutual inductance coefficient corresponds to a higher residual magnetic field and more significant coupling interference.Notably,the variation in residual magnetic field is substantially greater in the 2 m zone than in the 5 m zone.The 2 m zone exhibits a strong correlation between mutual inductance and residual magnetic field(R2=0.994).Through frequency optimization,the residual magnetic field in the 2 m zone can be reduced by more than 85%.That is,mutual inductance coupling between degaussing coils is a key factor determining the level of the residual magnetic field under extremely weak magnetic conditions.
孙津济;李兴龙;马剑豪;阚之棋;尚思涵;韩邦成
北京航空航天大学仪器科学与光电工程学院 北京 100191北京航空航天大学仪器科学与光电工程学院 北京 100191杭州极弱磁场国家重大科技基础设施研究院 杭州 310028北京航空航天大学仪器科学与光电工程学院 北京 100191北京航空航天大学仪器科学与光电工程学院 北京 100191北京航空航天大学仪器科学与光电工程学院 北京 100191
信息技术与安全科学
大型磁屏蔽装置消磁互感耦合规律
Magnetic shielding device of large scaledemagnetizationmutual inductance of coilcoupling law
《电工技术学报》 2026 (20)
6779-6790,12
国家自然科学基金项目(52525501,52475239)和浙江省博士后科研择优项目(ZJ2025046)资助.
评论