Sequential Modeling of Liquid Hydrogen Leakage,Dispersion and Post-Ignition Thermal Hazards in Semi-Open Railway StationsOA
This study develops a sequential numerical modelling framework to elucidate the transient evolution of liquid hydrogen(LH_(2))leakage,pool evaporation,hydrogen dispersion,and post-ignition thermal hazards in a representative semi-open railway station.The framework couples a source-term integral model for LH_(2) pool evaporation with computational fluid dynamics(CFD),in which the time-dependent liquid-pool radius and evaporation mass flow rate are introduced as transient inlet conditions through a user-defined function.The Realizable k-𝜀turbulence model and species transport equations are employed to predict the subsequent dispersion of gaseous H_(2) within the station environment,accounting for the influence of large-span roofs,locomotives,and structural columns on hydrogen migration and retention.At 3.0 s after leakage initiation,the analysis branches into non-ignited dispersion and ignition/combustion scenarios.For the latter,the instantaneous H_(2) concentration,temperature,and velocity fields are used to initialize ignition at(−0.7,−3.6,0.5)m.The results show that the LH_(2) evaporation mass flow rate reaches approximately 3.6 kg/s at 3.7–3.8 s,while the liquid-pool radius increases to approximately 1.2 m at 4.2 s.In the non-ignited scenario,the 4 vol%H_(2) cloud reaches a front position of 22.42 m and a length of 28.92 m at 9 s,while residual hydrogen continues to migrate and dilute for approximately 200 s.In the ignition/combustion scenario,the maximum flame temperature reaches 2193.5 K at 3.0 s.The combustion analysis is limited to post-ignition thermal effects and does not consider deflagration-induced overpressure or structural response.
Dapeng Jin;Yuejiao Wang;Bin Liu;Yichi Zhang;Sichao Zhang;Pengbo Yin
CRRC Academy(Qingdao)Co.,Ltd.,Qingdao,China College of Automotive and Energy Engineering,Tongji University,Shanghai,ChinaSchool of Civil Engineering and Architecture,Hebei University of Engineering Science,Shijiazhuang,ChinaHebei Key Laboratory of Cryogenic Energy Storage,School of Mechanical Engineering,Shijiazhuang Tiedao University,Shijiazhuang,ChinaBeijing Xingyou Engineering Project Management Co.,Ltd.,Beijing,ChinaHebei Key Laboratory of Cryogenic Energy Storage,School of Mechanical Engineering,Shijiazhuang Tiedao University,Shijiazhuang,ChinaCollege of Chemical Engineering,Fuzhou University,Fuzhou,China
交通工程
Liquid hydrogen leakagetransient source termhydrogen dispersionthermal hazardrailway station
《Fluid Dynamics & Materials Processing》 2026 (9)
P.175-201,27
supported by the Natural Science Foundation of Fujian Province(Grant No.2025J0113).
评论