地铁列车新型横向格栅送风特性仿真研究与实验验证OA
Simulation Research and Experimental Verification of Air Supply Characteristics of New Transverse Grille in Metro Trains
为优化地铁夏季空调送风体验,本文设计了一种新型横向格栅避免冷空气直吹带来的不适感,并优化送风均匀性以得到更合理的气流组织.利用计算流体动力学对车辆送风系统进行仿真分析,并与实测数据对比,评估送风均匀性.结果表明:风道内压力与速度分布存在梯度,进风口与格栅出口静压较中部高约 20%~35%,格栅下方风速仅为0.05~0.10 m/s,可有效避免冷风直吹.客室压差低于 5 Pa,风速主要在 0.07~0.20 m/s,符合舒适性标准.仿真结果与实测一致性较好,大部分偏差小于 10%,验证了模型的可靠性,可为轨道车辆空调系统优化设计提供参考.
To optimize the air conditioning supply experience of the subway in summer,a new type of horizontal grille is designed to avoid the discomfort caused by the direct blowing of cold air,and the uniformity of air supply is optimized to obtain a more reasonable air flow organization.The vehicle air supply system is simulated and analyzed by using computational fluid dynamics,and is compared with the measured data to evaluate the uniformity of air supply.The results indicate that pressure and velocity in the air duct exhibit clear gradients,with static pressure at the inlet and grille outlet about 20%–35%higher than that in the middle section.The airflow velocity beneath the grille is only 0.05–0.10 m/s,effectively preventing cold-air direct blowing.The cabin pressure difference is below 5 Pa,and airflow velocity mainly ranges from 0.07 m/s to 0.20 m/s,meeting comfort standards.The simulation results agree well with experimental data,with most deviations below 10%,verifying the model's reliability and providing a reference for optimizing air distribution in railway vehicle HVAC systems.
薛明洋;刘政;万进全;陈鹏舟;孙小雨;田博;王鹤淇;臧建彬
北京地铁车辆装备有限公司,北京 100079北京地铁车辆装备有限公司,北京 100079浙江翱翔智能科技股份有限公司,浙江 嘉兴 314000同济大学汽车与能源学院,上海 201800北京地铁车辆装备有限公司,北京 100079北京地铁车辆装备有限公司,北京 100079北京地铁车辆装备有限公司,北京 100079同济大学汽车与能源学院,上海 201800
通用工业技术
地铁列车送风均匀性计算流体动力学
Metro trainAir supply uniformityComputational fluid dynamics
《制冷技术》 2026 (3)
53-57,5
评论