Experimental analysis on the seismic performance of novel prefabricated reinforced concrete column-steel beam composite joints
针对装配式钢-混凝土组合结构节点的抗震韧性问题,提出一种基于榫式插接的新型装配式钢筋混凝土柱-钢梁组合节点(PRCSJs).对3个PRCSJs边节点试件进行拟静力试验,以轴压比和后浇混凝土强度为参数变量,研究不同参数对PRCSJs承载能力、延性、耗能能力及性能退化的影响,并对节点进行刚性评估.结果表明:PRCSJs的破坏模式为梁端连接破坏,满足"强柱弱梁"抗震设计准则;PRCSJs的滞回曲线呈饱满梭形,具有明确的弹性、弹塑性及破坏受力 3阶段;PRCSJs的平均延性系数在2.76~4.88之间,等效黏滞阻尼系数在0.28~0.31之间,展现出良好的延性和耗能;后浇超高性能混凝土能有效提升PRCSJs的承载能力,增强节点整体变形性能,降低后浇区混凝土的裂缝开裂;轴压比在0.15~0.3范围内时,增大轴压比能有效提高初始刚度,但会显著降低节点延性和刚度退化性能;PRCSJs在有侧移时为半刚性节点和部分强度节点.
A novel prefabricated reinforced concrete column-steel beam composite joint(PRCSJ)based on tenon-mortise connection is proposed to address seismic resilience issues in prefabricated steel-concrete composite structures.A series of quasi-static tests was conducted on three edge PRCSJ specimens,with the axial compression ratio and the strength of post-cast concrete serving as parameter variables.The objective of this study was to investigate the effects of different parameters on the load-bearing capacity,ductility,energy dissipation capacity,and performance degradation of PRCSJs,and to evaluate the rigidity of the joints.The findings suggest that PRCSJs demonstrated connection failure at the beam end,thereby adhering to the"strong column-weak beam"seismic design principle.The PRCSJs demonstrate plump spindle-shaped hysteresis curves,with distinct elastic,elastic-plastic,and failure stages.The average ductility coefficients range from 2.76 to 4.88 and the equivalent viscous damping coefficients from 0.28 to 0.31,demonstrating good ductility and energy dissipation capacity.The utilization of post-cast ultra-high performance concrete has been demonstrated to enhance the load-bearing capacity of PRCSJs,augment overall joint deformation,and mitigate cracking in the post-cast concrete area.Increasing the axial compression ratio(0.15~0.3)has been shown to enhance the initial stiffness whilst reducing ductility and stiffness degradation capacity of the joints.PRCSJs act as semi-rigid and partial-strength joints under lateral displacement.
于素健;丁晓娟;李昊;王江涛;吴成龙;王永洪;段海洋;李大壮
青岛理工大学科技发展集团有限公司,山东 青岛 266520||青岛理工大学 土木工程学院,山东 青岛 266520青岛理工大学 土木工程学院,山东 青岛 266520青岛理工大学 土木工程学院,山东 青岛 266520山东高速工程建设集团有限公司,济南 250014青岛理工大学 土木工程学院,山东 青岛 266520青岛理工大学 土木工程学院,山东 青岛 266520中青建安建设集团有限公司,山东 青岛 266000山东高速工程建设集团有限公司,济南 250014
建筑与水利
预制装配式组合节点轴压比超高性能混凝土刚性评估
prefabricatedcomposite jointaxial compression ratioultra-high performance concreterigidity assessment
《土木与环境工程学报(中英文)》 2026 (5)
13-23,11
国家自然科学基金(52208482)山东省自然科学基金(ZR2021QE046) National Natural Science Foundation of China(No.52208482)Natural Science Foundation of Shandong(No.ZR2021QE046)