T形截面部分包覆钢-混凝土组合柱的抗震性能OA
Seismic performance of partially encased composite(PEC)steel-concrete columns with T-shaped sections
为研究T形截面部分包覆钢-混凝土组合柱(简称T形PEC柱)的抗震性能,对轴压比和主钢件构造不同的5根T形PEC柱试件进行往复加载试验,其中主钢件包括实腹钢和钢腹板开孔的蜂窝钢.结合有限元分析,考察主钢件腹板开孔、轴压比对T形PEC柱抗震性能的影响.结果表明,5个T形PEC柱试件的最终破坏为柱底附近钢翼缘塑性软化并伴随着附近混凝土压溃,为典型的截面压弯破坏模式;所有柱试件的荷载-位移滞回曲线均较饱满,同一加载级下的3个滞回环几乎重合,表现出良好的抗震耗能能力和承载力稳定性;钢腹板开孔将降低T形PEC柱的变形能力、延性和耗能能力;增加轴压比会增加T形PEC柱的抗侧刚度和承载力,但会降低柱的变形能力、延性和耗能能力;全截面塑性方法和数值积分方法均能较好地估计恒定轴力和弯矩共同作用下T形PEC柱的截面抗弯承载力.
The present study investigates the seismic performance of partially encased composite steel-concrete columns with T-shaped sections(abbreviated as T-PEC columns).Five T-PEC column specimens with different axial compression ratios and main steel component(MSC)configurations are tested under cyclic horizontal load.Furthermore,MSCs are available in various forms,including solid-web steel and honeycomb steel with openings in the steel web.Based on the test and finite element(FE)analysis results,the impact of steel web openings and the axial compression ratio on the seismic performance of T-PEC columns is investigated.The findings indicate that all T-PEC column specimens failed in proximity to the column base,exhibiting plastic softening of the steel flange and adjacent concrete crushing.This is indicative of a typical cross-section compression-bending failure mode.The load-displacement hysteresis curves of all specimens were full,with the hysteresis loops at the same loading level almost coinciding,indicating effective energy dissipation and load-bearing stability.Steel web openings degraded deformability,ductility,and energy dissipation capacity of T-PEC columns.As the axial compression ratio increased,the lateral stiffness and lateral resistance capacity of the T-PEC columns increased,but the deformability,ductility,and energy dissipation capacity decreased.Both the full-section plasticity method and numerical integration method provided reasonably accurate estimates of the flexural capacity of the T-PEC column sections under the action of compression-bending load.
赵必大;慎天池;朱雄;管云杰
浙江工业大学 土木工程学院,杭州 310023浙江工业大学 土木工程学院,杭州 310023浙江工业大学 土木工程学院,杭州 310023浙江工业大学 土木工程学院,杭州 310023
建筑与水利
钢-混凝土组合柱T形截面柱抗侧承载力抗弯承载力刚度延性
steel-concrete composite columnT-shaped section columnlateral bearing capacityflexural capacitystiffnessductility
《土木与环境工程学报(中英文)》 2026 (5)
1-12,12
浙江省自然科学基金(LY20E080020) Zhejiang Provincial Natural Science Foundation(No.LY20E080020)