首页|期刊导航|人民长江|三峡水库汛期控制水位方案下机组出力最优分配

三峡水库汛期控制水位方案下机组出力最优分配OA

Optimal load allocation of hydropower units under flood-season water level control scheme in Three Gorges Reservoir

中文摘要英文摘要

年汛限水位静态控制与"以电定水"的机组出力分配模式制约了水库洪水资源利用与机组发电的提升空间.为此,构建三峡水库汛期控制水位方案,在此基础上提出"以水定电"机组出力最优分配模型,采用动态规划算法高效求解此模型,并开展实例分析.结果表明:在特丰水年、丰水年、平水年、枯水年4 种典型来水情景下,相比年汛限水位下机组出力均分方案,汛期控制水位下机组出力均分方案通过提高有效发电水头和增加拦蓄利用水量,在不降低防洪标准的前提下,每年汛期发电量增加4.29 亿~7.67 亿 kWh(增幅0.94%~2.09%),弃水量减少0.93 亿~8.63 亿 m3(降幅0.20%~4.01%),机组耗水率降低0.05~0.10 m3/kWh(降幅1.00%~1.99%);相比汛期控制水位下机组出力均分方案,汛期控制水位下"以水定电"机组出力优化分配方案通过动态调整机组启停组合与负荷分配,使机组在高效率区间运行,可增加发电量 1.35 亿~2.67 亿kWh(增幅0.30%~0.71%),降低机组耗水率0.01~0.04 m3/kWh(降幅 0.22%~0.80%).研究成果可为水库洪水资源利用率与机组发电效率的协同提升提供科学支撑.

The static regulation of annual flood-limited water levels and the"power-oriented"unit load dispatch mode re-strict flood resources utilization and limit the generation potential for hydropower units.This study formulated a flood-season wa-ter level control scheme for the Three Gorges Reservoir and further proposed a water-driven optimal unit load allocation model based on the established scheme.Dynamic programming was adopted for efficient model solving,and case studies were conducted.Results for four typical inflow scenarios(extremely wet,wet,normal,and dry)show that,compared with the equal-load scheme under the annual flood limited water level,the equal-load scheme under the flood-season water level control elevates the effec-tive water head and increases the impounded floodwater available.Without compromising flood control standards,this scheme dur-ing the flood season increases power generation by 429~767 million kWh(an increase of 0.94%~2.09%),reduces spilled vol-ume by 93~863 million m3(a reduction of 0.20%~4.01%),and decreases the unit water consumption rate by 0.05~0.10 m3/kWh(a reduction of 1.00%~1.99%).Furthermore,compared with the equal-load-distribution scheme under the flood-season water level control,the"water-driven"optimal unit load allocation scheme dynamically adjusts unit start-stop combi-nations and load allocation,which keeps operating units within high efficiency intervals,further increasing power generation by 135~267 million kWh(an increase of 0.30%~0.71%)and reducing unit water consumption by 0.01~0.04 m3/kWh(a reduc-tion of0.22%~0.80%).The findings provide scientific support for improving flood resource utilization and hydropower unit generation efficiency.

周研来;杨晨运;李嘉暄;沈號然;覃兰馨

武汉大学 水资源工程与调度全国重点实验室,湖北 武汉 430072武汉大学 水资源工程与调度全国重点实验室,湖北 武汉 430072武汉大学 水资源工程与调度全国重点实验室,湖北 武汉 430072武汉大学 水资源工程与调度全国重点实验室,湖北 武汉 430072武汉大学 水资源工程与调度全国重点实验室,湖北 武汉 430072

建筑与水利

机组出力最优分配"以水定电"模式汛期控制水位动态规划算法三峡水库

optimal unit load dispatchwater-driven dispatchflood-season water level controldynamic programming al-gorithmThree Gorges Reservoir

《人民长江》 2026 (9)

28-36,9

国家自然科学基金项目(52479022)

10.16232/j.rmcj.20260817

评论