双能CT碘图影像组学特征对甲状腺乳头状癌侧颈区淋巴结转移的诊断价值OA
Value of dual-energy CT iodine map derived radiomics features in diagnosing the lateral cervical lymph node metastasis in papillary thyroid cancer
目的:探讨双能CT(dual energy CT,DECT)碘图影像组学特征对甲状腺乳头状癌(papillary thyroid cancer,PTC)侧颈区淋巴结转移(lateral cervical lymph node metastasis,LLNM)的诊断价值.方法:回顾性分析2022年6月—2024年6月于南京医科大学第一附属医院术前行DECT检查并经病理证实的200例PTC患者临床和影像资料,共纳入777枚淋巴结(其中379枚转移淋巴结,398枚非转移淋巴结).将患者按7∶3的比例随机分配到训练集与验证集中.纳入淋巴结相关的CT图像特征参数:大小、形状、边缘、强化程度、是否合并钙化及囊变、是否结外侵犯.纳入淋巴结DECT定量参数:动脉期和静脉期的碘浓度、标准化碘浓度、有效原子序数、标准化有效原子序数和能谱曲线斜率.同时从动脉期和静脉期碘图中手动勾画感兴趣区,提取影像组学特征.结果:除结外侵犯外,转移淋巴结与非转移淋巴结的所有图像特征及DECT定量参数差异均有统计学意义(P均<0.05).与传统影像特征模型[训练集曲线下面积(area under curve,AUC)=0.803,95%CI:0.765~0.841;验证集 AUC=0.804,95%CI:0.748~0.861]相比,DECT定量参数模型(训练集AUC=0.939,95%CI:0.918~0.960;验证集AUC=0.933,95%CI:0.901~0.965)、影像组学模型(训练集AUC=0.977,95%CI:0.966~0.988;验证集AUC=0.931,95%CI:0.900~0.962)和联合模型(训练集AUC=0.977,95%CI:0.965~0.988;验证集AUC=0.938,95%CI:0.908~0.968)对LLNM的诊断效能均更优(P均<0.05).训练集中影像组学模型诊断效能优于DECT定量参数模型(P<0.01),影像组学模型与联合模型效能相仿(P=0.950).结论:DECT碘图影像组学特征对PTC患者LLNM具有较高的诊断价值.
Objective:To investigate the diagnostic value of radiomics features derived from iodine map of dual energy CT(DECT)in diagnosing lateral cervical lymph node metastasis(LLNM)in patients of papillary thyroid cancer(PTC).Methods:A retrospective analysis was performed on the clinical and imaging data of 200 patients with PTC who underwent preoperative DECT at the First Affiliated Hospital of Nanjing Medical University between June 2022 and June 2024,all with pathological confirmation.A total of 777 lymph nodes were included,comprising 379 metastatic lymph nodes and 398 non-metastatic lymph nodes.Patients were randomly allocated into the training and validation sets at a ratio of 7∶3.Clinical and CT features of lymph nodes,including size,shape,margin,enhancement degree,calcification,cystic change,and extranodal extension were included.Quantitative DECT parameters including iodine concentration,normalized IC,effective atomic number,normalized Zeff and slope of energy spectrum curve in arterial and venous phase.Radiomics features were manually extracted from arterial and venous phase iodine maps by sketching region of interest.Results:All clinical and DECT features showed significant differences between LLNM and non-LLNM(all P<0.05)except for extranodal extension.Compared with the conventional imaging model[training set,area under curve(AUC)=0.803,95%CI:0.765-0.841;validation set,AUC=0.804,95%CI:0.748-0.861],the DECT quantitative parameter model(training set,AUC=0.939,95%CI:0.918-0.960;validation set,AUC=0.933,95%CI:0.901-0.965),radiomics model(training set,AUC=0.977,95%CI:0.966-0.988;validation set,AUC=0.931,95%CI:0.900-0.962)and combined model(training set,AUC=0.977,95%CI:0.965-0.988;validation set,AUC=0.938,95%CI:0.908-0.968)showed excellent diagnostic performance in both training and validation set(P<0.05).In the training set,radiomics model was superior to DECT quantitative parameter model(P<0.01),while no significant difference was observed between the radiomics and combined models(P=0.950).Conclusion:Radiomics features extracted from iodine mapping extraction have high diagnostic value in diagnosing LLNM in PTC patients.
周雨;周燕;许泳康;旷欣汝;沈美萍;斯岩;王勇;苏国义;吴飞云
南京医科大学第一附属医院放射科,江苏 南京 210029南京医科大学第一附属医院放射科,江苏 南京 210029南京医科大学第一附属医院放射科,江苏 南京 210029南京医科大学第一附属医院放射科,江苏 南京 210029南京医科大学第一附属医院放射科,江苏 南京 210029南京医科大学第一附属医院放射科,江苏 南京 210029南京医科大学第一附属医院放射科,江苏 南京 210029南京医科大学第一附属医院放射科,江苏 南京 210029南京医科大学第一附属医院放射科,江苏 南京 210029
医药卫生
甲状腺乳头状癌双能CT淋巴结转移影像组学
papillary thyroid cancerdual energy CTlymph node metastasisradiomics
《南京医科大学学报(自然科学版)》 2026 (10)
1518-1526,1552,10
国家自然科学基金(82171928,82471980)江苏省自然科学基金(BK20241983)
评论