首页|期刊导航|辽宁工程技术大学学报(自然科学版)|近断层复杂空间厂房的BRB减震结构体系有限元分析

近断层复杂空间厂房的BRB减震结构体系有限元分析OA

Finite element analysis on BRB seismic performance structural system for complex spatial industrial buildings near faults

中文摘要英文摘要

针对近断层地震作用下,复杂空间工业厂房因大开洞、大跨度及刚度分布不均导致的抗震薄弱问题,以汾酒2030技改项目酿酒车间为工程背景,提出框架-屈曲约束支撑(BRB)减震体系.基于SAUSAGE建立三维弹塑性有限元模型,并采用SATWE进行小震弹性校核;选取36条近断层地震动记录,按向前方向性脉冲(FD)、滑冲效应脉冲(FS)和非脉冲型(N)分组,分析结构层间位移角、楼层加速度、顶部侧移及BRB延性需求.结果表明:该厂房标高3.500 m和4.800 m层开洞率分别为87%和92%,Y向存在9~12 m大跨度区域,局部刚度薄弱.增设BRB后,结构第一周期由0.847 s降至0.707 s;小震下X向、Y向最大层间位移角分别为1/583和1/595.罕遇地震下,FD、FS、N组顶部侧移峰值分别为0.435 m、0.523 m和0.218 m,BRB累计位移延性系数中位数分别为8.46、18.49和14.19.BRB可有效提升大开洞及长跨区域抗侧能力,并通过滞回耗能降低主体结构损伤;FS地震动对结构位移响应和BRB累计延性需求最不利,应作为近断层复杂厂房BRB设计的控制工况.

To address the problem of seismic weakness caused by large openings,large spans and uneven stiffness of complex space industrial plants under near-fault earthquakes,this study proposed a frame-buckling restrained brace(BRB)damping based on the brewing workshop of Fenjiu 2030 technical transformation project.A three-dimensional elastic-plastic finite element model was established based on SAUSAGE,and SATWE was used to check the elasticity of small earthquakes.Thirty-six near-fault ground motions were selected and grouped according to forward directional pulse(FD),slip effect pulse(FS)and non-pulse type(N).The inter-story displacement angle,floor acceleration,top lateral displacement and BRB ductility demand of the structure were analyzed.The results show that the opening rates of the 3.500 m and 4.800 m floors of the plant are 87%and 92%,respectively,with a large span of 9-12 m in the Y direction,resulting in localized stiffness weaknesses.After adding BRB,the first period of the structure reduced from 0.847 s to 0.707 s.Under frequent-occurrence earthquakes,the maximum inter-story displacement angles in X and Y directions are 1/583 and 1/595,respectively.Under the rare-occurrence earthquakes,the peak lateral displacement at the top of FD,FS and N groups are 0.435 m,0.523 m and 0.218 m,respectively,and the median values of cumulative displacement ductility coefficient of BRB are 8.46,18.49 and 14.19,respectively.BRB effectively enhance the lateral resistance of large openings and long-span areas,and reduce the damage of the main structure through hysteretic energy dissipation.The FS ground motion induce the most adverse structural displacement response and the cumulative ductility demand of BRB,and thus should serve as the control condition of BRB design for near-fault complex plant.

朱国庆;胡正平;董皓雪;王高宁;吴秀峰

辽宁工程技术大学 土木工程学院,辽宁 阜新 123000辽宁工程技术大学 土木工程学院,辽宁 阜新 123000北京华清联合工程技术有限公司,北京 102101北京华清联合工程技术有限公司,北京 102101辽宁工程技术大学 土木工程学院,辽宁 阜新 123000

建筑与水利

防屈曲支撑钢筋混凝土框架近断层脉冲型地震动复杂空间厂房抗震性能有限元分析

buckling-restrained bracedreinforced concrete frame structurenear-fault pulse-like ground motionscomplex spatial industrial buildingseismic performancefinite element analysis

《辽宁工程技术大学学报(自然科学版)》 2026 (5)

574-584,11

辽宁省教育厅高校基本科研基金项目(2025-Z0129)汾酒2030技改原酒产储能扩建项目(24-2495)