相较于机械式断路器,固态断路器(solid-state circuit breaker,SSCB)因其短路发生时切断电流无电弧及可靠性高的优点在直流电网短路保护中受到广泛关注.文中设计了一种具有自动隔离故障能力的直流固态断路器,该断路器由短路判定模块与故障电流缓冲模块组成,短路发生后可以在没有外部控制系统的情况下切除故障电流.文中对该固态断路器不同的工作状态进行分析,建立相应的数学模型,并以此作为参数设计的理论依据,在设计完成后与现有的固态断路器在10 kV/500 A直流电网的短路切除仿真中进行对比,仿真结果表明:加入具有自动隔离故障能力的直流固态断路器后,输电线的运行损耗仅增加0.025%,因此该断路器不影响电路的正常运行;当直流电网发生短路故障后,该断路器能在5 ms内自动关断,且可以平滑的吸收故障电流使固态开关所承受的峰值电压不超过线路电压的1.5倍,对直流电网具有可靠的保护作用.

Solid state circuit breaker(SSCB),compared with mechanical circuit breakers,has received much atten-tion in short-circuit protection of DC network due to its such advantages as arc-free current interruption upon short circuit occurrence and high reliability.In this paper,a DC SSCB with automatic fault isolation capability is designed.The SSCB consists of a short-circuit judgement module and a fault current buffer module which,in case of short cir-cuit,can clear the fault current without an external control system.The different operating states of this solid-state circuit breaker is analyzed,the corresponding mathematical model is set up and used as the theoretical basis for pa-rameter design.After completion of the design,it is compared with the existing solid state circuit breaker in short cir-cuit interuption simulation at 10 kV/500 A DC network.The simulation result shows that after addition of the SSCB with automatic fault isolation capability,the operation loss of the transmission line is only increased by 0.025%,there-fore the circuit breaker does not affect the normal operation of the circuit.After the occurrence of short circuit fault of the DC network,the circuit breaker can automatically interrupt within 5 ms and smoothly absorb the fault current so that the peak voltage sustained by the SSCB does not exceed 1.5 times the line voltage,thereby providing reliable pro-tection for the DC network.

吴铁洲;赵瑞;李厚佳

湖北工业大学太阳能高效利用及储能运行控制湖北省重点实验室,武汉 430063湖北工业大学太阳能高效利用及储能运行控制湖北省重点实验室,武汉 430063湖北工业大学太阳能高效利用及储能运行控制湖北省重点实验室,武汉 430063

直流故障固态断路器短路判定故障电流缓冲峰值电压

DC faultssolid-state circuit breakersshort-circuit determinationfault current bufferingpeak voltage

《高压电器》 2026 (10)

15-24,31,11

国家自然科学基金(52177212)湖北工业大学科技项目(锂离子电池储能电站充放电系统安全运行关键技术).Project Supported by National Natural Science Foundation of China(52177212),Science and Technology Project of Hubei University of Technology(Key Technology for Safe Operation of Charge/Discharge System of Lithium-ion Battery Storage Power Plant).

10.13296/j.1001-1609.hva.2026.10.002