首页|期刊导航|锅炉技术|燃煤机组不同熔盐储热系统调峰特性研究

燃煤机组不同熔盐储热系统调峰特性研究OA

Research on Peak-Shaving Characteristics of Different Molten Salt Thermal Energy Storage Systems in Coal-Fired Units

中文摘要英文摘要

熔盐储热与火电机组的耦合能够显著提高机组灵活性,并实现深度调峰的目标.针对 1 台 350 MW机组,提出了 4 种可行的熔盐储热系统方案:MCR、MCR+RL、MF 和 MF+RL.研究结果表明:4 种熔盐储热系统均能增加调峰深度,增加调峰深度最有效的方案是同时抽取主蒸汽和热再热蒸汽进行储热.从增加调峰能力的角度评价,最优方案为 MCR+RL.4 种熔盐储热系统均会不同程度上影响机组的运行性能.加装储热系统后,系统运行灵活性的增加是以机组原有性能为代价的.HPT 单位输出功(火用)损失受储热方案影响明显,方案 MCR 与方案 MCR+RL 使单位输出功(火用)损失增加了 0.3,而 IPT 单位输出功(火用)损失受储热方案影响并不明显.整个储放循环系统全过程煤耗率增加最低的方案为 MF,储放循环增加的煤耗率为 3 g/kW·h.整个储放循环全过程热效率最高的方案也是 MF,全过程热效率为 0.373.从对机组运行性能影响的角度评价,最优方案为 MF,利用潜热的储热方式机组运行性能更优.

The coupling of molten salt thermal energy storage with coal-fired power units can significantly improve unit flexibility and achieve deep peak-shaving objectives.For a 350 MW unit,four feasible molten salt thermal energy storage system schemes are proposed:MCR,MCR+RL,MF,and MF+RL.The results show that all four systems can increase the peak-shaving depth,with the most effective scheme being the simultaneous extraction of main steam and hot reheat steam for heat storage.From the perspective of enhancing peak-shaving capability,the optimal scheme is MCR+RL.All four systems affect the operational performance of the unit to varying degrees.The increase in system operational flexibility after installing the heat storage system comes at the cost of the unit's original performance.The exergy loss per unit output work of the HPT(High-Pressure Turbine)is significantly influenced by the heat storage schemes,with schemes MCR and MCR+RL increasing this loss by 0.3,while the IPT(Intermediate-Pressure Turbine)shows no significant impact.The scheme with the lowest increase in coal consumption rate during the entire charge-discharge cycle is MF,with an incremental coal consumption rate of 3 g/kWh.The scheme with the highest overall thermal efficiency during the entire cycle is also MF,with a cycle thermal efficiency of 0.373.From the perspective of impact on unit operational performance,the optimal scheme is MF,and the heat storage approach utilizing latent heat achieves better unit operational performance.

曹传胜;唐畅;赵璐;程帅;许祥;杨远;张云龙;张扬;于洁

湖北省电力规划设计研究院有限公司,湖北 武汉 430040湖北省电力规划设计研究院有限公司,湖北 武汉 430040湖北省电力规划设计研究院有限公司,湖北 武汉 430040湖北省电力规划设计研究院有限公司,湖北 武汉 430040华中科技大学 煤燃烧与低碳利用全国重点实验室,湖北 武汉 430074湖北省电力规划设计研究院有限公司,湖北 武汉 430040湖北省电力规划设计研究院有限公司,湖北 武汉 430040华中科技大学 煤燃烧与低碳利用全国重点实验室,湖北 武汉 430074华中科技大学 煤燃烧与低碳利用全国重点实验室,湖北 武汉 430074

能源科技

熔盐储热煤耗率灵活性系统往返效率潜热

molten salt thermal energy storagecoal consumption rateflexibilitysystem round-trip efficiencylatent heat

《锅炉技术》 2026 (5)

63-71,9

国家自然科学基金面上项目(52076091)

评论