首页|期刊导航|锅炉技术|超超临界四角切圆燃烧锅炉再热汽温偏差优化试验研究

超超临界四角切圆燃烧锅炉再热汽温偏差优化试验研究OA

Optimization Experimental Study on the Reheat Steam Temperature Deviation in Ultra-Supercritical Tangentially Fired Boiler

中文摘要英文摘要

某电厂四角切圆燃烧锅炉低温再热蒸汽交叉进入高温再热器后汽温偏差增大,分析认为流场分布不均、局部煤粉燃烧推迟是导致再热汽温偏差增大的主要原因.试验研究了辅助风门开度、分离燃尽风门开度、垂直摆角及水平摆角对再热汽温偏差及高温再热器壁温分布的影响.研究结果表明:辅助风门开度、分离燃尽风门开度及垂直摆角对再热汽温偏差影响较小,1、2 号角分离燃尽风燃烧器反切,3、4 号角分离燃尽风燃烧器正切有助于减小汽温偏差,分离燃尽风水平摆角调整后再热汽温偏差减小约 5℃.

In a tangentially fired boiler of a certain power plant,the steam temperature deviation of the low-temperature reheated steam increased after it crossed into the high-temperature reheater.Analysis indicated that uneven flow field distribution and delayed pulverized coal combustion in local zones were the main causes of the increased reheat steam temperature deviation.Experimental studies were conducted on the effects of auxiliary air damper opening,separated overfire air(SOFA)damper opening,vertical tilt angle,and horizontal yaw angle on the reheat steam temperature deviation and the wall temperature distribution of the high-temperature reheater.The results show that the auxiliary air damper opening,SOFA damper opening,and vertical tilt angle have relatively minor effects on the reheat steam temperature deviation.The reverse tangential firing of the SOFA burners at corners 1 and 2,and the same-direction tangential firing of those at corners 3 and 4,help reduce the temperature deviation.After adjusting the horizontal yaw angle of the SOFA burners,the reheat steam temperature deviation decreased by approximately 5℃.

张飞;朱武松;李炎

国能陈家港发电有限公司,江苏 盐城 224631国能陈家港发电有限公司,江苏 盐城 224631西安热工研究院有限公司,陕西 西安 710054

能源科技

四角切圆锅炉再热汽温偏差分离燃尽风水平摆角壁温

tangentially fired boilerreheat steam temperature deviationseparated overfire airhorizontal yaw anglewall temperature

《锅炉技术》 2026 (5)

32-38,7

评论