面向新型配电网的智能化一二次融合环保气体环网柜关键技术与试验验证OA
Key Technologies and Experimental Validation of Intelligent Primary-Secondary Integrated Eco-Friendly Gas-Insulated Ring Main Units for New-Generation Distribution Networks
针对新型配电网中环保气体环网柜绝缘裕度不足、一二次融合结构电场畸变及测量抗干扰能力受限等问题,构建智能化一二次融合环保气体环网柜总体架构,采用电场均匀化、内置传感器协同布局、测量链路抗干扰优化及三工位与断路器联动控制方法,实现绝缘、测量与故障闭锁一体化设计.型式试验和单相接地真型试验表明,样机成套计量精度达0.5 级,相电压基本误差为 0%,进线/出线相电流误差分别为-0.15%~+0.30%和-0.15%~+0.60%,接地故障识别准确率为 100%,闭锁响应时间<100 ms,满足工程应用要求.
To address insufficient insulation margin,electric-field distortion,and limited anti-interference capability of eco-friendly gas-insulated ring main units in new-generation distribution networks,the overall architecture of intelligent primary-secondary integrated eco-friendly gas-insulated ring main units is constructed.Electric-field equalization,coordinated built-in sensor layout,measurement-chain anti-interference optimization,and coordinated control between the three-position switch and circuit breaker are adopted to integrate insulation design,measurement,and fault interlocking.Type tests and real-type single-phase grounding tests show that the prototype achieves Class 0.5 metering accuracy,a basic phase-voltage error of 0%,incoming and outgoing phase-current errors of-0.15%to+0.30%and-0.15%to+0.60%,respectively,a grounding fault identification accuracy of 100%,and an interlocking response time of less than 100 ms,meeting engineering application requirements.
王健;王杰
申恒电力设备有限公司,浙江 乐清 325699申恒电力设备有限公司,浙江 乐清 325699
信息技术与安全科学
新型配电网环保气体一二次融合环网柜故障检测
new-generation distribution networkeco-friendly gasprimary-secondary integrationring main unitsfault detection
《电器与能效管理技术》 2026 (9)
40-46,7
评论