目的:对比不同迭代去金属伪影(iMAR)算法降低腰椎内固定术后金属伪影的效果.方法:前瞻性筛选腰椎内固定术后患者,不采用和采用 8种被推荐用于不同临床场景(神经线圈、牙齿填充物、脊柱植入物、肩部植入物、起搏器、胸腔线圈、臀部植入物、四肢植入物)的 iMAR算法进行图像重建.分别在螺钉长轴最佳横断面图像和无明显伪影横断面图像,勾画椎体、椎管、竖脊肌和皮下脂肪的感兴趣区(ROI),记录 CT值和标准差(SD),计算各个部位的 CT差异值(ΔCT)、平均背景 SD、平均伪影 SD和各个部位的伪影指数(AI).以不采用 iMAR的图像作为对照组,采用 iMAR算法的图像作为试验组,对其金属伪影去除效果及其对诊断的影响分别进行主客观评价.比较主客观评价结果.结果:研究共纳入 36名患者,平均年龄为(62.75±12.23)岁,男性 22名(61.1%).扫描容积 CT剂量指数(CTDIvol)中位数(四分位数)16.25(14.55,19.62)mGy,剂量长度乘积(DLP)中位数(四分位数)448.45(410.52,566.88)mGy·cm.与不采用 iMAR算法的图像相比,采用脊柱 iMAR算法图像的各个部位的 ΔCT、平均伪影 SD和各个部位的 AI均显著更低.与其他 iMAR算法图像相比,采用脊柱 iMAR算法图像的肌肉 ΔCT、脂肪 ΔCT、平均伪影 SD和各个部位的 AI显著更低.与不采用 iMAR算法的图像相比,采用脊柱 iMAR算法图像的主观评分更高.结论:与用于其他临床场景的 iMAR算法相比,脊柱植入物的iMAR算法去除腰椎内固定术后患者金属伪影的效果更为理想,推荐用于临床诊断.

Objective:To aim of this study was to compare the performance of different iterative metal artifact reduction(iMAR)algorithms at reducing metal artifacts after lumbar spine internal fixation surgery.Methods:Patients who underwent internal lumbar spine fixation were prospectively enrolled.Image reconstruction was performed without the iMAR algorithm and with eight recommended iMAR algorithms tailored for different clinical scenarios(neurocoils,dental fillings,spinal implants,shoulder implants,pacemakers,thoracic coils,hip implants,and extremity implants).The regions of interest(ROI),namely,the vertebral body,spinal canal,erector spinae,and subcutaneous fat,were delineated on optimal cross-sectional images along the long axis of the screws,as well as on cross-sectional images without obvious artifacts.The computed tomography(CT)values and their standard deviation(SD)were recorded,and the CT value difference(ΔCT)of each region,average background SD,average artifact SD,and artifact index(AI)value of each region were calculated.Tanking images without the iMAR algorithm were used as the control group,and those reconstructed with the iMAR algorithm were used as the experimental group.The effectiveness of metal artifact removal and its impact on diagnosis were assessed subjectively and objectively.Subjective and objective evaluation results were compared.Results:Thirty-six patients,including 22 males(61.11%),were included in the study,with a mean(age±SD)of(62.75±12.23)years.The median(interquartile range)of the volume CT dose index value(CTDIvol)was 16.25(14.55,19.62)mGy,and the median(interquartile range)of the dose-length product(DLP)was 448.45(410.52,566.88)mGy·cm.The ΔCT values of each region,average artifact SD value,and AI values of each region were significantly lower in images reconstructed with the spinal iMAR algorithm than those reconstructed without the iMAR algorithm.The muscle ΔCT value,fat ΔCT value,average artifact SD value,and AI values of each region were significantly lower in images reconstructed with the spinal iMAR algorithm than in those reconstructed using other iMAR algorithms.The subjective scores were significantly higher for images reconstructed with the spinal iMAR algorithm than for those reconstructed without the iMAR algorithm.Conclusion:Compared with the iMAR algorithms used for other clinical scenarios,the iMAR algorithm for spinal implants was more effective at removing metal artifacts in patients after lumbar spine internal fixation surgery and is recommended for clinical diagnosis.

王思连;张欢;姚伟武;钟京谕;陈黎伟;黄普珍;金汉樯;星月;胡扬帆;许芷菡;宋阳;褚敬申

上海交通大学医学院附属同仁医院影像科,上海 200336||上海市柔性医疗机器人重点实验室,上海 200336上海交通大学医学院附属瑞金医院放射科,上海 200050上海交通大学医学院附属同仁医院影像科,上海 200336||上海市柔性医疗机器人重点实验室,上海 200336上海交通大学医学院附属同仁医院影像科,上海 200336||上海市柔性医疗机器人重点实验室,上海 200336上海交通大学医学院附属同仁医院影像科,上海 200336||上海市柔性医疗机器人重点实验室,上海 200336上海交通大学医学院附属同仁医院影像科,上海 200336||上海市柔性医疗机器人重点实验室,上海 200336上海交通大学医学院附属仁济医院骨科,上海 200127上海交通大学医学院附属同仁医院影像科,上海 200336||上海市柔性医疗机器人重点实验室,上海 200336上海交通大学医学院附属同仁医院影像科,上海 200336||上海市柔性医疗机器人重点实验室,上海 200336西门子医疗诊断影像CT科研合作部,上海 200126西门子医疗磁共振科研市场部,上海 200126上海交通大学医学院附属瑞金医院科技发展处《诊断学理论与实践》编辑部,上海 200050

数理科学

腰椎迭代算法金属伪影图像质量

lumbar vertebraeiterative algorithmmetal artifactimage quality

《CT理论与应用研究》 2026 (6)

1069-1078,10

国家自然科学基金(基于CT增强影像组学联合代谢组学构建急性胰腺炎重症化智能早期预警模型研究(82302183)基于注意力−可解释图文信息挖掘创建膝骨关节炎交互式诊断报告系统(82471935))上海市卫生健康委员会项目(骨病多模态报告和数据系统(Bone-RADS)规范精准风险评估并优化诊疗管理建议的临床研究(20244Y0214))脊柱微创诊疗关键技术与材料实验室开放基金项目(基于人工智能的脊柱退行性病变CT影像研究(2024JZWC-ZDA04)高级弥散模型DXI平台稳健性及其在腰椎间盘退变定量评价及突出定位诊断中的应用研究(2024JZWC-YBA07)).

10.15953/j.ctta.2025.460