首页|期刊导航|中国医学工程|基于红外-散斑多模态实时预警的艾灸标准化操作与风险管理体系构建与评价研究

基于红外-散斑多模态实时预警的艾灸标准化操作与风险管理体系构建与评价研究OA

Construction and evaluation of moxibustion standardized operation and risk management system based on infrared speckle multimodal real-time early warning

中文摘要英文摘要

目的 构建一套融合红外-散斑多模态实时预警技术的艾灸标准化操作与风险管理体系,并验证其预警效能及在降低不良事件、提升操作规范性与改善患者体验中的综合效果.方法 采用技术构建与前瞻性临床验证相结合的研究设计.首先,通过多学科协作,开发基于红外与散斑同步数据采集的实时预警系统,其核心为构建"热-血流变耦合指数(THFI)",并依据回顾性数据设定分级预警阈值(初级预警线THFI=3.5,高级预警线THFI=5.0).将该系统整合入标准化管理路径.随后,于2023年6月起实施该体系,采用前后对照设计,选取体系实施前(2022年9月至11月,对照组,n=125)与实施后(2023年6月至8月,干预组,n=125)的患者,比较两组效果.主要评价指标包括预警系统效能(灵敏度、特异度)、客观效应指标[红外温度-时间曲线下面积(IRT-T-AUC)、血流灌注峰值(PU)、THFI峰值(THFI-max)]及临床结局指标(不良事件发生率、护士关键操作依从率、患者舒适度与满意度及护士知信水平).结果 预警系统对不良事件的预测灵敏度为90.0%,特异度为96.7%,受试者操作特征(ROC)曲线下面积(AUC)为0.952.干预组客观指标得到有效控制:IRT-T-AUC为(36.13±5.37)℃·s,低于对照组的(49.01±6.92)℃·s(P<0.001);PU峰值为(59.24±8.22)PU,低于对照组的(76.21±10.41)PU(P<0.001);THFI-max为3.12±1.01,低于对照组的5.82±1.61(P<0.001).临床结局显著改善:不良事件总发生率由12.8%降至3.2%(P<0.05),中重度事件实现零发生;护士关键操作总依从率由76.5%提升至95.1%(P<0.001);患者治疗舒适度评分由(6.2±1.5)分升至(8.1±1.2)分(P<0.001),总体满意度由88.0%提高至95.2%(P<0.05).结论 本研究成功构建的艾灸多模态实时预警与标准化管理体系,能够实现风险的动态监测与即时干预,有效控制刺激强度,显著提升临床安全性与护理质量,为艾灸技术的客观化、智能化风险管理提供了实证依据.

[Objective]To construct a set of standardized operation and risk management system of moxibustion combined with infrared speckle multimodal real-time early warning technology,and verify its early warning efficiency and comprehensive effect in reducing adverse events,improving operation standardization and improving patient experience.[Methods]A research design combining technology construction and prospective clinical verification was used.First,through multi-disciplinary cooperation,a real-time early warning system based on infrared and speckle synchronous data acquisition was developed.The core of the system was to build a"thermo-hemorheological coupling index(THFI)"and set a hierarchical early warning threshold based on retrospective data(primary early warning line THFI=3.5,advanced early warning line THFI=5.0).Integrate the system into the standardized management path.Then,the system was implemented from June 2023.A controlled design was used to select patients before the implementation of the system(September to November 2022,control group,n=125)and after the implementation(June to August 2023,intervention group,n=125).The effects of the two groups were compared.The main evaluation indicators included the effectiveness of early warning system(sensitivity,specificity),objective effect indicators[area under the infrared temperature-time curve(IRT-T-AUC),peak blood perfusion(PU),THFI-max]and clinical outcome indicators(incidence of adverse events,nurse operation compliance,patient comfort and satisfaction).[Results]The sensitivity and specificity of the early warning system for predicting adverse events were 90.0%and 96.7%,respectively.The area under the receiver operating characteristic curve was 0.952.The objective indicators of the intervention group were effectively controlled:IRT-T-AUC was 36.13±5.37℃·s,significantly lower than 49.01±6.92℃·s of the control group(P<0.001);the peak value of PU was 59.24±8.22 PU,which was significantly lower than 76.21±10.41 PU in the control group(P<0.001);THFI-max was 3.12±1.01,significantly lower than 5.82±1.61 in the control group(P<0.001).Clinical outcomes were significantly improved:the total incidence of adverse events decreased from 12.8%to 3.2%(P<0.05),and the occurrence of moderate and severe events was zero;the total compliance rate of nurses'key operations increased from 76.5%to 95.1%(P<0.001);the treatment comfort score increased from 6.2±1.5 to 8.1±1.2(P<0.001),and the overall satisfaction increased from 88.0%to 95.2%(P<0.05).[Conclusion]The multimodal real-time early warning and standardized management systemof moxibustion successfully constructed in this study can realize the dynamic monitoring and immediate intervention of risk,effectively control the stimulation intensity,significantly improve the clinical safety and nursing quality,and provide an evidence-based scheme for the objective and intelligent risk management of moxibustion technology.

张吉明;杨鑫;刘蕊;曹文静

甘肃中医药大学附属医院 心血管内科,甘肃 兰州 730020||甘肃中医药大学附属医院 针灸科,甘肃 兰州 730020甘肃中医药大学附属医院北院 心血管科,甘肃 兰州 730020甘肃中医药大学附属医院北院 心血管科,甘肃 兰州 730020甘肃中医药大学附属医院 心血管内科,甘肃 兰州 730020

医药卫生

艾灸风险管理多模态融合红外热成像激光散斑血流成像实时预警

moxibustionrisk managementmultimodal fusioninfrared thermographylaser speckle blood flow imagingreal-time warning

《中国医学工程》 2026 (8)

15-20,6

甘肃省卫生健康行业科研计划项目(GSWSHL2023-38)

10.19338/j.issn.1672-2019.2026.08.004

评论