基于步高数据的双足步态对称性检测系统研究OACHSSCD
A bipedal gait symmetry detection system based on foot clearance data
目的:针对光学步态分析设备成本高、惯性测量单元在位移解算中易累积漂移等问题,提出一种基于超声波测距的低成本双足步态对称性检测系统.方法:在双足鞋侧布置足跟、足尖超声波传感器,采集关键点对地距离,建立足部二维几何模型解算足部姿态和步高,并估算步长、步频;引入步高对称性指数(symmetry index,SI)、归一化互相关(normalized cross-correlation,NCC)、时延估计(time-delay estimation,TDE)、能量比(energy ratio,ER)及均方根误差(root mean square error,RMSE)构建步态对称性评价体系.招募 10 名健康受试者模拟正常、慌张及拖曳步态进行验证.结果:步长估计结果的平均绝对误差(mean ab-solute error,MAE)、均方根误差(RMSE)、偏差及决定系数R2 分别为 2.76 cm、3.54 cm、0.37 cm 与 0.945;步频估计对应的各项指标分别为 4.47 步/min、5.7 1 步/min、0.1 0 步/min 与 0.959.步态对称性分析结果显示:正常步态与慌张步态的步态均衡系数 ER 均趋近于 1,归一化互相关系数 NCC 整体大于 0.9;慌张步态的足尖、足跟时序偏差 TDE 分别缩短至 436 ms、424 ms;拖曳步态的不对称指数 SI 升高至 1.223,足跟区域对应的ER、RMSE 与时序偏差 TDE 分别增大至 18.410、30.01 mm、968 ms.结论:该系统能够高精度解算步长、步频及步态对称性特征,可为低成本步态监测与临床康复评估提供技术支撑.
Aims:To address the high cost of optical gait analysis systems and the cumulative drift of inertial measurement units in displacement estimation,this study proposes a low-cost bilateral gait symmetry detection system based on ultrasonic ranging.Methods:Heel and toe ultrasonic sensors were mounted on both shoes to measure foot-to-ground distances.A two-dimensional foot model was used to estimate foot posture,step height,step length,and cadence.Gait symmetry was evaluated using the step-height symmetry index(SI),normalized cross-correlation(NCC),time-delay estimation(TDE),energy ratio(ER),and root mean square error(RMSE).Ten healthy participants were recruited to simulate normal,shuffling,and dragging gaits for experimental verification.Results:For step-length estimation,the mean absolute error(MAE),root mean square error(RMSE),bias and coefficient of determination(R2)were 2.76 cm,3.54 cm,0.37 cm and 0.945,respectively.The corresponding metrics for cadence estimation were 4.47 steps/min,5.71 steps/min,0.10 steps/min and 0.959.Symmetry analysis revealed that the equilibrium ratio(ER)of normal and shuffling gaits was close to 1;and the normalized cross-correlation(NCC)was overall higher than 0.9.The temporal deviation error(TDE)of shuffling gait decreased to 436 ms(toe)and 424 ms(heel).For dragging gait,the symmetry index(SI)rose to 1.223,while the heel-related ER,RMSE and TDE increased to 18.410,30.01 mm and 968 ms correspondingly.Conclusions:The proposed system can accurately extract stride length,cadence and gait symmetry features,which provides a reference for low-cost gait monitoring and rehabilitation assessment.
胡宇超;张斌;洪晓雪;王斌锐;周坤
中国计量大学 机电工程学院,浙江 杭州 310018中国计量大学 机电工程学院,浙江 杭州 310018温州市人工智能局,浙江 温州 325088中国计量大学 机电工程学院,浙江 杭州 310018中国计量大学 机电工程学院,浙江 杭州 310018
信息技术与安全科学
步态分析超声波传感器几何建模步态对称性
gait analysisultrasonic sensorgeometric modelinggait symmetry
《中国计量大学学报》 2026 (2)
182-191,10
国家自然科学基金项目(No.62303434),浙江省自然科学基金项目(No.LMS25F030001)
评论