荧光标记法用于医院环境物体表面清洁消毒效果的评价分析OA
Evaluation and analysis of surface cleaning and disinfection effectiveness of objects in hospital environment using fluorescence labeling method
目的 分析荧光标记法用于医院环境物体表面清洁消毒的效果,为院内管理和预防感染提供参考.方法 选择广州医科大学附属番禺中心医院加强监护病房(ICU)、手术室、普通病房、妇产科病房、普通门诊大厅、行政办公室等高频接触表面和普通接触表面为实验对象,使用荧光标记法、腺苷三磷酸(ATP)生物荧光检测法、微生物培养法三种方法同步评估清洁消毒结果,分析三种方法检测结果、不同区域和不同表面类型清洁消毒效果,以及清洁消毒效果相关因素.结果 荧光标记法、ATP生物荧光检测法和微生物培养法的检测合格率分别为70.00%(168/240)、77.50%(186/240)和82.50%(198/240),总体比较差异有统计学意义(x2=10.621,P=0.005);两两比较并经Bonferroni校正后,仅荧光标记法与微生物培养法的检测合格率差异有统计学意义(P=0.004).荧光标记法单个采样点的检测耗时最短、成本最低.高度和中度风险区域高频接触表面的荧光标记法检测合格率均低于同区域普通接触表面(P=0.041、0.015),低度风险区域两种表面类型比较,差异无统计学意义(P=0.775).高度、中度和低度风险区域总检测合格率分别为58.75%、70.00%和81.25%,总体比较差异有统计学意义(x2=9.643,P=0.008);两两比较并经Bonferroni校正后,仅高度风险区域合格率低于低度风险区域(P=0.006).240个采样点中综合合格165个,综合合格率为68.75%.工作年限、清洁流程及消毒方式与综合判定结果相关(均P<0.05),文化程度与综合判定结果无明显相关性(P=0.965).结论 荧光标记法操作简便、检测耗时短、成本低,可直观识别清洁死角,适用于医院环境物体表面清洁消毒效果的日常监测与针对性改进.
Objective To assess the effectiveness of fluorescent labeling in monitoring environmental surface cleaning and disinfection within hospital settings,and to offer reference data for nosocomial infection management and prevention.Methods This investigation was carried out in Panyu Central Hospital Affiliated to Guangzhou Medical University.High-touch and general-contact surfaces were chosen from multiple areas,including the(intensive care unit)ICU,operating rooms,general wards,obstetrics and gynecology wards,outpatient halls,and administrative offices.Cleaning efficacy was concurrently evaluated using three techniques:fluorescent labeling,ATP bioluminescence,and microbial culture.The detection outcomes of these methods were compared,and cleaning performance was examined across different regions and surface categories.Influencing factors associated with cleaning effectiveness were also explored.Results The qualification rates of fluorescence labeling,ATP bioluminescence,and microbial culture were 70.00%(168/240),77.50%(186/240),and 82.50%(198/240),respectively,with a significant overall difference(x²=10.621,P=0.005).After Bonferroni correction,only fluorescence labeling and microbial culture differed significantly(adjusted P=0.004).Fluorescence labeling had the shortest testing time and lowest cost per sampling site.In high-and moderate-risk areas,qualification rates were lower for high-touch surfaces than for general-contact surfaces(P=0.041 and 0.015,respectively),whereas no significant difference was observed in low-risk areas(P=0.775).Overall qualification rates in high,moderate,and low-risk areas were 58.75%,70.00%,and 81.25%,respectively(x²=9.643,P=0.008);after Bonferroni correction,only the high-versus low-risk comparison remained significant(adjusted P=0.006).Overall,165 of 240 sampling sites(68.75%)met all three qualification criteria.The composite outcome was associated with cleaners'length of service,cleaning procedures,and disinfection methods(all P<0.05),but not with educational level(P=0.965).Conclusion Fluorescent labeling is a userfriendly,timeefficient,and economical tool for routine surveillance of surface disinfection.It effectively pinpoints cleaning blind spots,thus facilitating targeted remedial actions in hospital hygiene management.
吉倩;卢燕冰;廖科萍
广州医科大学附属番禺中心医院后勤保障科,广州 511400广州医科大学附属番禺中心医院后勤保障科,广州 511400广州医科大学附属番禺中心医院医务科,广州 511400
荧光标记法医院环境物体表面清洁消毒
fluorescence labeling methodhospital environmentobject surfacecleaning and disinfection
《中华灾害救援医学》 2026 (8)
896-901,6
评论