为探究受限空间内地铁列车空调散热的特性与隧道轨顶排风的作用,本文于夏季典型高温日对某市地铁的三条线路进行测试,测得环境温度与列车空调的冷凝器进排风温度等参数,并计算出其散热量与能效,同时针对性的提出两条改善方案.结果表明:中间车厢因载客与气流累积的原因,导致其热负荷明显高于头车;老旧线路轨行区积热导致冷凝进风温偏高;地下封闭空间引起排风回流,使冷凝器进风温度高于环境,空调能效降低;开启轨顶排风可改善冷凝器进排风的气流,降低进风温度并提升能效.研究分析出了散热的热力学成因,并为列车系统节能优化提供了实际依据.单纯依赖轨顶排风系统难以实现根本性改善,而需结合结构优化与运行策略协同调控.通过优化车隧顶高度差至1.8~2.3 m,在常规35 s停站工况下即可满足散热需求,避免大规模土建改造;同时结合主动降载技术进行补偿,使系统在接近高温保护前平滑降低负荷,避免故障停机.主动降载策略在低载客条件下可实现50%负荷调节,在高载客情况下维持临界运行区间,从"防停机"角度保障系统连续性运行.
To investigate the heat dissipation characteristics of metro train air conditioning in confined spaces and the role of tunnel over-track exhaust systems,measurements were conducted on three metro lines in a city during typical high-temperature summer days.Parameters including ambient temperature and condenser inlet/outlet air temperatures of the train air conditioning systems were recorded,based on which the heat dissipation capacity and energy efficiency were calculated.Two targeted improvement strategies were subsequently proposed.The results show that due to passenger load and accumulated airflow,the thermal load on intermediate carriages is significantly higher than that on leading cars.In older lines,heat accumulation in the track area results in elevated condenser inlet air temperatures.The enclosed underground space induces exhaust air recirculation,causing condenser inlet temperatures to exceed ambient levels and reducing air conditioning energy efficiency.Activating the over-track exhaust system improves the airflow around the condenser,lowering inlet temperatures and enhancing efficiency.The thermodynamic causes of heat dissipation were identified,providing a practical basis for energy-saving optimization of train systems.Sole reliance on over-track exhaust systems is insufficient for fundamental improvement;instead,structural optimization and coordinated operational strategies are required.By optimizing the height difference between the train and tunnel crown to 1.8-2.3 m,heat dissipation demands can be met under a typical 35-second station dwell time without large-scale civil works.Simultaneously,active load reduction technology compensates by smoothly reducing load before the system approaches high-pressure protection thresholds,thereby preventing fault-induced shutdowns.Under low passenger loads,the active load reduction strategy achieves 50%load regulation,while under high loads it maintains operation within a critical range,ensuring system continuity from the perspective of shutdown prevention.
周剑峰;蔡瑞晶;李江鹏;潘昊川;吴妍;王毅峰
中车南京浦镇车辆有限公司,江苏南京,210031中车南京浦镇车辆有限公司,江苏南京,210031同济大学汽车与能源学院,上海,200092同济大学汽车与能源学院,上海,200092同济大学建筑与城市规划学院,上海,200092同济大学汽车与能源学院,上海,200092
交通工程
地铁车辆列车空调受限空间隧道轨顶排风改善措施
Metro VehicleTrain Air ConditioningConfined SpaceTunnel Track Top ExhaustImprovement Measures
《制冷》 2026 (4)
40-48,9
中国中车股份有限公司科技研究开发计划项目(项目编号:2024CCB218)
评论