综合医院通风空调系统平疫结合设计OA
Integrated Design of Ventilation and Air Conditioning Systems for General Hospitals in Normal and Epidemic Conditions
本文以武汉航天城同济医院为研究案例,针对新冠疫情暴露的综合医院传染病收治能力不足问题,开展综合医院平疫结合设计方法研究.论文明确了住院部、急诊科、重症ICU、手术部等科室的平疫结合设计要求.重点论述住院楼护理单元、门诊医技平疫转化区域的通风及空调系统设计,以及医院空调冷热源系统平疫结合设计原则.研究平急两用医院的设计思路与转换策略,提出平时按综合医院正常运行、疫时快速转换,同时兼顾日常运行节能与设备维护便捷性的设计目标,从总体布局与医患流线、通风空调系统转换、冷热源配置等方面制定具体设计方案,为综合医院平疫结合建设提供实践参考.
Taking Tongji Hospital in Wuhan Aerospace City as a case study,this paper conducts a research on the design method of general hospitals integrating both ordinary and epidemic situations,aiming at the problem of insufficient capacity for infectious disease treatment in general hospitals exposed by the CO VID-19 pandemic.It clarifies the design requirements for such integration in departments including inpatient wards,emergency departments,ICUs and operating rooms.The paper focuses on the design of ventilation and air conditioning systems for nursing units in inpatient buildings and convertible areas between normal and epidemic conditions in outpatient and medical technical zones,as well as the design principles of integrated cold and heat source systems for hospital air conditioning under both ordinary and epidemic situations.It explores the design concepts and conversion strategies of dual-purpose hospitals for daily and emergency use,and puts forward the design objectives of normal operation as a general hospital in routine periods and rapid conversion during epidemic periods,while giving consideration to energy conservation in daily operation and convenience of equipment maintenance.Specific design schemes are formulated from the aspects of overall layout,patient and medical staff flow patterns,conversion of ventilation and air conditioning systems,and cold and heat source configuration,so as to provide practical references for the construction of general hospitals integrating both ordinary and epidemic situations.
汪庆军;雷建平;陈焰华
中信建筑设计研究总院有限公司,武汉,430014中信建筑设计研究总院有限公司,武汉,430014中信建筑设计研究总院有限公司,武汉,430014
建筑与水利
平疫转换三区两通道负压病房空气净化双风机机组
Normal-epidemic ConversionThree Zones and Two PassagesNegative-pressure WardAir PurificationDual-fan Unit
《制冷》 2026 (4)
17-21,68,6
评论