首页|期刊导航|中国电机工程学报|考虑PMU数据特征的新能源场站扰动检测方法

考虑PMU数据特征的新能源场站扰动检测方法OA

Disturbance Detection Method for Renewable Generation Resources Considering the Characteristics of PMU Data

中文摘要英文摘要

相量测量单元(phasor measurement unit,PMU)可为新能源场站的动态特性分析和功率波动监测提供数据支撑.由于场站的运行环境恶劣,现场已部署的PMU易出现量测数据异常现象,连续的不良数据将影响真实扰动的检测.基于某新能源示范基地现场的量测数据,文中提出一种考虑PMU 数据特征的新能源场站扰动检测方法.首先,分析新能源场站中4 种PMU频率不良数据的现象,揭示异常时刻不良数据与扰动在不同PMU量测时空相似性方面的特征差异;其次,考虑点异常和序列异常的局部和全局特征,提出改进局部离群因子算法的点异常检测方法,改进过程结合聚类算法全面比较点的密度差异,有效降低了虚警率;然后,提出改进去噪变分自编码器模型的序列异常检测方法,该方法对原始数据进行特征增强,提取信息最丰富的特征向量输入模型,同时引入加权重构误差并设定动态阈值,有效提升了检测精度;为进一步区分不良数据和扰动,提出改进动态核相关的扰动检测方法,通过计算时空相似性矩阵以度量不良数据和扰动在时空维度的特征差异性,进而实现扰动事件的准确检测;最后,通过仿真和实测数据验证所提方法可有效检测扰动并滤除不良数据,保障了PMU 数据的可靠性.

The Phasor Measurement Unit provides data support for dynamic analysis and power fluctuation monitoring in renewable energy stations.Due to harsh operating environments,deployed PMUs often exhibit measurement anomalies,and continuous faulty data can impact the detection of real disturbances.Based on measurement data from a renewable energy demonstration base,this paper proposes a disturbance detection method for renewable energy stations considering PMU data characteristics.The method analyzes four types of PMU frequency anomalies in renewable energy stations and reveals the differences in spatiotemporal similarity between faulty data and disturbances across different PMUs.Considering both point and sequence anomalies'local and global features,this paper proposes an improved Local Outlier Factor algorithm for point anomaly detection,which effectively reduces false alarm rate by incorporating clustering algorithms to compare the differences in point density.An improved denoising variational autoencoder model is introduced for sequence anomaly detection,enhancing feature extraction and setting dynamic thresholds,which improves detection accuracy.To further distinguish faulty data from disturbances,this paper develops an improved dynamic kernel correlation disturbance detection method,which calculates a spatiotemporal similarity matrix to measure feature differences,ensuring accurate disturbance event detection.Simulation and real data confirm the effectiveness of the proposed method.

廖梦竹;刘灏;毕天姝

新能源电力系统全国重点实验室(华北电力大学),北京市 昌平区 102206新能源电力系统全国重点实验室(华北电力大学),北京市 昌平区 102206新能源电力系统全国重点实验室(华北电力大学),北京市 昌平区 102206

信息技术与安全科学

扰动检测同步相量测量局部离群因子去噪变分自编码器动态核相关

disturbance detectionsynchronous phasor measurementlocal outlier factordenoising variational autoencoderdynamic kernel correlation

《中国电机工程学报》 2026 (17)

6167-6178,中插3,13

国家自然科学基金项目(52377098). Project Supported by National Natural Science Foundation of China(52377098).

10.13334/j.0258-8013.pcsee.251230

评论