脉冲辐射源三维成像系统的性能参数研究OA

Study on the Performance Parameters of 3D Imaging System for Pulsed Radiation Source

中文摘要英文摘要

脉冲辐射源的X射线与中子3维成像诊断对理解惯性约束聚变和Z箍缩过程中复杂的等离子体形态至关重要.受装置空间限制,可用成像光轴数量极少(通常小于等于5),导致3维重建问题高度不适定,重建算法的设计与多轴联合诊断系统的性能参数是影响重建质量的关键因素.针对ICF(Inertial Confinement Fusion)内爆结构特征,研究了多光轴针孔联合诊断系统的空间布局及系统偏差对辐射源3维重建结果的影响.以基于柱谐函数分解约束迭代初值的极少角度3维重建算法为基础,仿真分析了 3维空间中2~5轴成像系统位于不同布局时的重建效果.研究发现,最优空间布局可分为两类场景:当光轴数量为2、3时,应将光轴均垂直于准对称轴并在水平面均匀设置;当光轴大于等于4时,在水平布局基础上,沿准对称轴方向增设一轴,可在极少光轴条件下获得更高质量的重建结果.在仿真各类系统偏差对重建质量的影响中,中心关联偏差对重建质量的影响最为显著.三轴等角分布时,若两轴系统中心在水平和垂直方向均偏移总尺寸的7.94%,结构相似性(structural similarity,SSIM)指标会下降至0.843 5;投影图像尺寸比例偏差的影响次之,而光轴方位角关联偏差的影响最小.研究结论可为多轴联合诊断系统的结构设计提供数据支撑.

Three-dimensional(3D)imaging of X-ray and neutron emissions from pulsed radiation sources is crucial for understanding the complex morphology of inertial confinement fusion(ICF)and Z-pinch plasmas.However,due to spatial constraints in experimental facilities,the number of available imaging axes is very limited,typically no more than five,leading to a severely ill-posed problem in computed tomography(CT)reconstruction.Consequently,the design of reconstruction algorithms and the performance parameters of multi-axis joint diagnostic systems are key factors determining the reconstruction quality.Focusing on the implosion structure characteristics in ICF experiments,this paper investigates the effect of spatial configuration and systematic errors of a multi-axis pinhole imaging system on the 3D reconstruction of radiation sources.Based on a limited-angle 3D reconstruction algorithm that uses cylindrical harmonic decomposition(CHD)to constrain the initial values for iterative methods,this paper simulates the reconstruction performance of 2 to 5 imaging axes with different spatial layouts.The results indicate that optimal spatial configurations fall into two categories.When the number of projection angles is two or three,the imaging axes should be arranged perpendicular to the quasi-symmetry axis and uniformly distributed in the horizontal plane.As the number of axes increases,incorporating one imaging axis along the quasi-symmetry axis yields superior reconstruction quality with very few viewing angles.Among various system errors,the center correlation error has the greatest detrimental impact on reconstruction quality.In a simulated triaxis equiangular configuration,a misalignment of 7.94%in both horizontal and vertical directions between two imaging axes causes the structural similarity(SSIM)index to drop to 0.843 5.The size-ratio correlation error has a moderate effect,while the azimuthal angular correlation error exhibits the least influence.These findings provide data-driven guidance for the structural design of multi-axis joint diagnostic systems in ICF facilities.

张艳红;盛亮;李阳;张骞;高建鹏;张美;涂艳云;刘振;赵吉祯

西北核技术研究所,西安 710024西北核技术研究所,西安 710024西北核技术研究所,西安 710024西北核技术研究所,西安 710024西北核技术研究所,西安 710024西北核技术研究所,西安 710024西北核技术研究所,西安 710024西北核技术研究所,西安 710024西北核技术研究所,西安 710024

数理科学

3维图像重建空间布局系统偏差准对称轴脉冲辐射源

3D image reconstructionspatial configurationsystematic errorquasi-symmetry axispulsed radiation source

《现代应用物理》 2026 (4)

76-85,10

10.12061/j.issn.2095-6223.202603015

评论