首页|期刊导航|市政技术|基于等效静力与简化脉冲响应的高架桥-桩基体系抗风性能研究

基于等效静力与简化脉冲响应的高架桥-桩基体系抗风性能研究OA

Study on Wind Resistance Performance of Viaduct-Pile Foundation System Based on Equivalent Static Force and Simplified Impulse Response

中文摘要英文摘要

为评价滨海软土地区高架桥-桩基体系在设计强风作用下的整体响应,以温州市域铁路S3线为工程背景,建立了桥梁-墩柱-承台-桩基-分层土体三维有限元模型.明确了桥面横向为风压作用方向,按代表性高度15 m、A类地面粗糙度考虑风压高度变化,设计风压为0.681 6 kN/m2;梁墩连接按刚接等效处理,桩-土相互作用采用接触模拟.基于前20阶振型累计质量参与系数超过90%、第一阶频率为0.32 Hz(对应基本周期约3.13 s),设置持续3 s的单次半正弦风压脉冲,并与等效静力工况、0.2~1.0倍风压分级结果进行对比.结果表明:等效静力工况下,桥顶横向位移峰值为4.216 mm,且位移响应随风压近似呈线性增长;单次半正弦风压脉冲作用下,桥顶横向位移峰值为2.2~2.3mm,2类工况的变形均由上部结构向桩基及深层土体逐步衰减.在所采用的设计风压与简化脉冲条件下,该高架桥-桩基体系整体处于小变形状态;需要特别说明的是,该瞬态分析结果仅反映该特定脉冲工况下的响应特性,不能替代真实台风随机风场下的精细化动力分析.

To evaluate the global response of a viaduct-pile foundation system in coastal soft soil areas under design strong winds,a 3D finite element model consisting of bridge,pier,cap,pile foundation and layered soil mass is es-tablished with the Wenzhou Municipal Railway Line S3 as the engineering background.The transverse direction of the bridge deck is defined as the wind pressure loading direction.Wind pressure height variation is considered for a representative height of 15 m and terrain roughness category A,yielding a design wind pressure of 0.681 6 kN/m2.The beam-pier connection is simplified as rigid joint,and the pile-soil interaction is simulated by contact algorithm.Based on the fact that the cumulative mass participation factor of the first 20 modes exceeds 90%and the first-order frequency is 0.32 Hz(corresponding to a fundamental period of approximately 3.13 s),a single half-sine wind pressure pulse with a duration of 3 s is applied.The results are compared with those under the equivalent static load case and graded wind pressure ranging from 0.2 to 1.0 times the design value.The results show that the peak transverse dis-placement at the bridge top reaches 4.216 mm under the equivalent static case,and the displacement response in-creases nearly linearly with wind pressure.Under the single half-sine wind pressure pulse,the peak transverse dis-placement at the bridge top is 2.2~2.3 mm.The deformations in both cases gradually attenuate from the superstruc-ture down to the pile foundation and deep soil.Under the adopted design wind pressure and simplified pulse condi-tions,the viaduct-pile foundation system remains in a small-deformation state.It should be specially noted that the transient analysis results only reflect the response characteristics under this specific pulse case and cannot replace refined dynamic analysis under the random wind field of real typhoons.

苏尔想

温州信达交通工程试验检测有限公司,浙江温州 325100

交通工程

滨海软土高架桥桩基设计风荷载半正弦风压脉冲等效静力瞬态响应

coastal soft soilviaductpile foundationdesign wind loadhalf-sine wind pressure pulseequivalent static forcetransient response

《市政技术》 2026 (9)

66-71,131,7

10.19922/j.1009-7767.2026.09.066

评论