切向流超滤法辅助ELISA检测血清中A型肉毒毒素OA
Tangential flow filtration-assisted ELISA for detection of botulinum toxin type A in human serum
目的 建立切向流超滤法辅助ELISA检测人血清中A型肉毒毒素,以提高ELISA对A型肉毒毒素的检测灵敏度.方法 采用切向流超滤技术对血清样本中的A型肉毒毒素进行分离纯化,考察膜材质(包括改性聚醚砜、聚醚砜、混合纤维素酯)、中空纤维内径、截留分子量、膜表面积、进液流量、跨膜压差(包括24.13 kPa、134.45 kPa和189.61 kPa)及循环速率对毒素萃取效率的影响,优化超滤条件;对优化后的超滤前处理流程进行方法学验证,并将其与ELISA联用,应用于含低浓度A型肉毒毒素的临床血清样本检测.结果 改性聚醚砜对肉毒毒素的萃取效果最佳,达到79.17%,显著高于其他两种膜材质(P<0.05);跨膜压差为134.45 kPa时对肉毒毒素的回收率最高(达82.40%);进液流量、循环速率及膜纤维内径、截留分子量、膜表面积对萃取效果无显著影响(P>0.05).方法学验证显示,建立的切向流超滤法辅助ELISA检测人血清中A型肉毒毒素的回收率为90.0%~105.0%,变异系数低于10%;应用于临床血清样本检测,超滤辅助ELISA可检出单纯ELISA无法检出的低浓度A型肉毒毒素样本.结论 本研究成功建立了切向流超滤技术辅助ELISA检测人血清中A型肉毒毒素的方法,显著改善了ELISA对低浓度A型肉毒毒素的检测能力,为临床血清样本中低浓度A型肉毒毒素的精准检测提供了可靠、高效的技术方案.
Objective To establish tangential flow ultrafiltration(TFU)-assisted ELISA for enhancing the sensitivity of botulinum toxin type A(BoNT-A)detection in human serum.Methods TFU was employed to separate and purify BoNT-A from serum samples.The effects of various parameters on toxin extraction efficiency were systematically investigated to optimize the ultrafiltration condi-tions,including membrane material(including modified polyethersulfone,polyethersulfone,and mixed cellulose ester),hollow fiber inner diameter,molecular weight cut-off(MWCO),membrane surface area,feed flow rate,transmembrane pressure(TMP,including 24.13 kPa,134.45 kPa,and 189.61 kPa),and circulation rate.The optimized ultrafiltration pretreatment protocol was methodologi-cally validated and subsequently integrated with ELISA for the detection of low-concentration botulinum toxin type A in clinical serum samples.Results Modified polyethersulfone exhibited the best extraction efficiency for botulinum toxin,reaching 79.17%,which was significantly higher than that of the other two membrane materials(P<0.05).The highest recovery rate of botulinum toxin was achieved at a transmembrane pressure of 134.45 kPa.Influent flow rate,circulation rate,hollow fiber inner diameter,molecular weight cut-off,and membrane surface area had no significant effect on extraction efficiency(P>0.05).Methodological validation showed that the recovery rate of the established TFU-assisted ELISA for detecting BoNT-A in human serum ranged from 90.0%to 105.0%,with a coefficient of variation below 10%.When applied to clinical serum samples,TFU-assisted ELISA detected low-concentration BoNT-A that were undetectable by conventional ELISA alone.Conclusion This study successfully established a TFU-assisted ELISA method for the detection of BoNT-A in human serum.This approach significantly enhanced the detection sensitivity of conven-tional ELISA for low-concentration BoNT-A,offering a reliable and efficient technical platform for accurate quantification of trace BoNT-A in clinical serum samples.
王文秀;周伟;胡爽;邢荣荣;陈璇
山西医科大学药学院药物分析教研室,太原 030001||兰州生物技术开发有限公司兰州生物技术开发有限公司山西医科大学药学院药物分析教研室,太原 030001山西医科大学药学院药物分析教研室,太原 030001山西医科大学药学院药物分析教研室,太原 030001
医药卫生
A型肉毒毒素切向流超滤中空纤维膜ELISA方法学验证血清
botulinum toxin type Atangential flow filtrationhollow fiber membraneELISAmethod validationserum
《山西医科大学学报》 2026 (8)
938-945,8
国家自然科学基金项目(81973287)国家自然科学基金青年基金项目(22104076)
评论