首页|期刊导航|热力发电|变冷却条件下超临界二氧化碳动力系统瞬态特性研究

变冷却条件下超临界二氧化碳动力系统瞬态特性研究OA

Study on transient characteristics of a supercritical carbon dioxide power system under variable cooling conditions

中文摘要英文摘要

[目的]超临界二氧化碳布雷顿循环是热力发电领域的重要技术发展方向之一,具有广泛的热源兼容性,因此,研究循环运行过程中的动态特性具有重要意义.本文研究当冷却条件发生变化时,该系统从波动到稳定的动态变化过程.[方法]针对压缩机和涡轮机,采用稳态模型,对于系统换热器,在其稳态 FV 有限元模型数据的基础上构建了新的动态数学模型.[结果]研究表明,改变预冷器的冷却流量后,系统最迟在 200 s 左右即达到稳定状态.其中,当预冷器的冷却流量降至最小值的50%时,主压缩机效率约下降 0.5%;增加预冷器冷却流量可提升压缩机运行效率:当冷却流量在 25 s 线性增加至 175%,主压缩机在 75 s 达到稳定状态时,其效率可提高 0.8%;再压缩机在 200 s 后稳定,效率可提高0.2%;系统净输出功率在300 s后稳定,系统热效率降低 0.3%.[结论]因为主压缩机进口温度(306 K)接近 CO2 的临界点,所以增加预冷器冷侧水的质量流量易引起压缩机进口温度低于CO2的临界温度,导致压缩机内出现工质凝结,影响压缩机的稳定运行,而降低预冷器水侧流量则会导致系统净输出功率减小、热效率降低.

[Objective]The supercritical carbon dioxide Brayton cycle(SCBC)is an important technological development direction in the field of thermal power generation.The study of its dynamic process is of great significance to the application of this system.In this paper,a dynamic analysis model of the SCBC power system is established to analyze the transient characteristics when the cooling condition is changed.[Methods]For compressors and turbines,the steady-state model is used.For heat exchangers,a dynamic model is established based on the steady-state finite volume(FV)model,to analyze the transient characteristics of the system when cooling conditions change.[Results]The research result shows that after changing the cooling flow rate of the precooler,the system reaches a stable state at the latest within about 200 seconds.The main compressor is highly sensitive to changes in the flow rate on the water side of the precooler.When the flow rate of the precooler drops to 50%of the minimum value,the efficiency of the main compressor decreases by approximately 0.5%.Increasing the flow rate on the water side of the precooler can improve the operating efficiency of the compressor.When the flow rate linearly increases to 175%within 25 seconds,the main compressor tends to stabilize after 75 seconds,and the efficiency increases by 0.8%.But at this point,the state of the compressor inlet is already very close to the surge line.After 200 seconds,the recompressor becomes stabilized,and its efficiency increases by 0.2%.The net output power of the system stabilizes after 300 seconds,and the thermal efficiency of the system decreases by 0.3%.[Conclusion]As the inlet temperature(306 K)of the main compressor is close to the critical temperature of CO2,increasing the flow rate on the cold side of the precooler can easily cause the inlet temperature of the compressor to be lower than the critical temperature,affecting the stable operation of the compressor.Reducing the flow rate on the cold side of the precooler will lead to a decrease in the net output power of the system and a reduction in thermal efficiency.Therefore,adjusting the flow rate in the precooler can rapidly change the total power consumption of the compressor,thereby quickly influencing the net output power of the system.This study provides a reference for designing reasonable control strategies when disturbances occur in the cooling water side of the precooler for RCBC systems,aiming to shorten the system response time and mitigate detrimental fluctuations.

姜文熙;董鑫;赵远扬

青岛科技大学机电工程学院,山东 青岛 266061青岛科技大学机电工程学院,山东 青岛 266061青岛科技大学机电工程学院,山东 青岛 266061

超临界二氧化碳再压缩布雷顿循环瞬态特性预冷器流量变化

supercritical carbon dioxide recompression Brayton cycletransient characteristicsprecoolerflow rate variation

《热力发电》 2026 (8)

96-106,11

国家自然科学基金项目(52076114)山东省自然科学基金项目(ZR2020ME168) National Natural Science Foundation of China(52076114)Natural Science Foundation of Shandong Province(ZR2020ME168)

10.19666/j.rlfd.202510077

评论