基于RENA-3的粒子探测系统中低耦合电容影响研究OA
Research on Influence of Low Coupling Capacitance in the RENA-3-Based Particle Detection System
粒子探测系统的性能主要由其第一级放大电路决定,主要包括粒子辐射探测器和电荷灵敏放大器(Charge-sensitive preamplifier,CSA).探测器与前端读出电路之间的连接通常采用交流耦合方式,配备一个在0.01~0.1 μF的范围内的耦合电容,将CSA的输入与探测器隔离开来.专用集成电路(Application-specific inte-grated circuit,ASIC)RENA-3是一种多通道混合信号集成电路(Integrated circuit,IC),具有高能量分辨率和高时间分辨率的特点,专为粒子辐射探测器的读出电路而设计.行星际超低噪声三维能量粒子谱仪被设计为利用RENA-3作为前端电路,探测20~1 000 keV电子、25~12 000 keV质子和α粒子这样的离子.然而,RENA-3的最大输入电荷为54 fC,这限制了它的最大探测范围约为1 200 keV,这个能量不足以满足仪器质子探测的能量范围需求.虽然也可以采用其他ASIC,但现有的替代方案无法同时满足高精度和宽测量范围的要求.本文提出采用一个小的耦合电容,在电荷信号到达CSA输入之前对其进行衰减,来扩展ASIC的探测范围.该耦合电容的大小在皮法量级,需要小于探测器结电容.在这种配置下,杂散电容和耦合电容对电路性能的影响变得非常重要.本文提出了一种电路理论模型来计算从输入电荷到输出电压的传递函数,分析了耦合电容和杂散电容对粒子辐射检测系统的影响.使用已知参数的分立元件进行实验来验证理论模型.然后将该模型应用于 RE-NA-3系统并按照仪器指标进行相应电路优化.实验结果显示,通过减小耦合电容的方法能够将RENE-3的能量探测范围至少扩大到9 MeV,这个能量满足仪器的质子探测指标.最后,杂散电容对小耦合电容的读出电路影响较大,本文分析了不同杂散电容对电路的影响,认为不同电容大小的探测器应采取不一样的电路板布局,能够通过改变杂散电容的分布从而得到更高的信噪比.
The performance of a particle detection system is primarily determined by its first stage,which mainly includes a particle radiation detector and a charge-sensitive preamplifier(CSA).The connection between the detector and the front-end readout circuit is typically AC-coupled,which usually has a coupling capacitor in the range of 0.01-0.1 μF to isolate the input of the CSA from the detector.The application-specific integrated circuit(ASIC)readout electronics for nuclear applications 3(RENA-3)is a multi-channel mixed-signal integrated circuit(IC)offering high energy resolution and high time resolution,developed for the readout of particle radiation detectors.RENA-3 is employed as the front-end readout circuit for an interplanetary energetic particle telescope designed to detect 20-1 000 keV electrons,25-12 000 keV protons,and ions like alpha particles.However,the maximum input charge of RENA-3 is 54 fC,which limits its maximum detection range to about 1 200 keV and is insufficient for the proton channels.While other ASICs could be adopted,available alternatives do not simultaneously meet the requirements for both high precision and wide measurement range.This paper proposes the use of a small coupling capacitance to extend the range for proton detection by attenuating the charge signal before it reaches the CSA input.The coupling capacitance is on the order of picofarads,much smaller than the detector junction capacitance.In this configuration,stray capacitance and coupling capacitance become significant.A circuit theoretical model is proposed to calculate the transfer function from input charge to output voltage,analyzing the influence of coupling capacitance and stray capacitance on the particle radiation detection system.Experiments using discrete components with known parameters are conducted to validate the theoretical model.Finally,the model is applied to the RENA-3 system for optimization to meet the instrument's specifications,and certain RENA-3 parameters are derived.
杨芯;叶雨光;王玲华;于向前;施伟红;陈鸿飞;王游龙;王永福;宗秋刚;邹鸿
北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国||中国科学院国家空间科学中心太阳活动与空间天气国家重点实验室,北京 100190,中国北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国||中国科学院国家空间科学中心太阳活动与空间天气国家重点实验室,北京 100190,中国北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国||中国科学院国家空间科学中心太阳活动与空间天气国家重点实验室,北京 100190,中国北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国
信息技术与安全科学
交流耦合电路耦合电容杂散电容电路表现粒子辐射探测系统
AC-coupled circuitcoupling capacitancestray capacitancecircuit performanceparticle radiation detection system
《南京航空航天大学学报(英文版)》 2026 (4)
506-516,11
This work was supported in part by the National Natural Science Foundation of China under con-tracts(Nos.42127803,42225404,42150105)and the Na-tional Key R&D Program of China(No.2023YFC2808904).
评论