针对模块化多电平换流器(MMC)在无源控制策略下抗干扰性差问题,提出了一种无源-自抗扰 MMC 控制策略.首先建立 MMC 的欧拉-拉格朗日(Euler-Lagrange,E-L)模型,并证明其无源性,基于无源控制理论设计电流内环控制器.其次,根据二阶线性自抗扰理论,设计功率外环控制器并进行参数整定,快速补偿系统总扰动,为内环无源控制器提供稳定的参考信号,提升系统跟踪性能.最后采用 MATLAB/Simulink 进行仿真,在功率突变工况下,与传统 PI 控制、单一无源控制策略开展仿真对比试验,分析了系统在启动过程与功率阶跃扰动下的动态响应特性.结果表明,所提控制策略可有效提升系统响应速度及抗干扰能力.

To address the problem of poor anti-disturbance performance of the Modular Multilevel Converter(MMC)under the passivity-based control strategy,a novel MMC control strategy based on passivity and active disturbance rejection is pro-posed.First,the Euler-Lagrange(E-L)model of MMC is established and its passivity is proved,on the basis of which an in-ner current loop controller is designed in accordance with the passivity-based control theory.Then,according to the second-order linear Active Disturbance Rejection Control(ADRC)theory,an outer power loop controller is designed and its parame-ters are tuned to compensate for the total disturbance rapidly.This controller provides a fast and stable reference signal for the output of the inner passivity-based controller,thus improving the system tracking performance.Finally,simulations are carried out using MATLAB/Simulink software.Under the power mutation condition,the system responses during start-up and power step are analyzed through comparisons with the PI control and passivity-based control strategies.The results show that the designed control strategy improves the system response speed and anti-disturbance capability,verifying its effectiveness.

诸建彬;杨佳涵;王翠;孙晨;张耀方

江西水利电力大学 电气工程学院,江西 南昌 330099江西水利电力大学 电气工程学院,江西 南昌 330099江西水利电力大学 电气工程学院,江西 南昌 330099江西水利电力大学 电气工程学院,江西 南昌 330099江西水利电力大学 电气工程学院,江西 南昌 330099

信息技术与安全科学

模块化多电平换流器无源控制自抗扰控制复合控制

Modular Multilevel Converterpassivity-based controlactive disturbance rejection controlcompound control

《江西水利电力大学学报》 2026 (4)