核级电磁阀长期带电后的首次复位时间延长原因OA
Reasons for the prolonged first reset time of nuclear grade solenoid valves after long-term electrification
某核电厂使用的某型号核级电磁阀长期带电后,多次出现首次复位时间延长的问题.采用阀芯行程限位试验、润滑脂对比涂抹试验等方法对电磁阀首次复位时间延长的原因进行分析.结果表明:电磁阀先导活塞端面残留了润滑脂是导致其复位时间延长的主要原因,该润滑脂的黏度较大,且为非牛顿流体,显著增大了先导活塞端面与螺母端面的贴合分离阻力,致使活塞分离动作滞后,最终造成电磁阀长期带电后的首次复位时间延长.对在役电磁阀开展活塞端面残留润滑脂专项清理工作,同时优化完善新备件入厂验收技术规范,新增长期带电工况复位性能测试要求,可解决该型号核级电磁阀长期带电后首次复位时间延长的问题.
After using a certain type of nuclear grade solenoid valve in a nuclear power plant for a long time,there were multiple instances of prolonged first reset time.The reasons for the prolonged first reset time of the solenoid valve were analyzed using methods such as valve core stroke limit test and comparative grease application test.The results show that the residual lubricating grease on the end face of the solenoid valve pilot piston was the main reason for the prolonged reset time.The viscosity of the grease was high and it was a non-Newtonian fluid,which significantly increased the resistance to the separation of the pilot piston end face and the nut end face,resulting in a delay in the piston separation action and ultimately causing the first reset time of the solenoid valve to be prolonged after being charged for a long time.Special cleaning work would be carried out on residual lubricating grease on the piston end face of in-service solenoid valves.At the same time,the technical specifications for the acceptance of new spare parts would be optimized and improved,and new requirements for long-term live working condition reset performance testing would be added to solve the problem of prolonged first reset time for this type of nuclear grade solenoid valve after long-term electrification.
徐大亮
大亚湾核电运营管理有限责任公司,深圳 518124
通用工业技术
电磁阀首次复位时间延长润滑脂黏度非牛顿流体
solenoid valveprolonged first reset timegreaseviscositynon-Newtonian fluid
《理化检验-物理分册》 2026 (8)
29-34,6
评论