核电厂阀盖泄漏原因OA
Causes of valve cover leakage in nuclear power plants
某核电机组核取样系统隔离阀盖发生泄漏事故.采用宏观观察、渗透检测、化学成分分析、力学性能测试、扫描电镜及能谱分析、金相检验等方法对阀盖泄漏的原因进行分析.结果表明:阀盖内表面存在两条沿轴向分布的裂纹,阀盖变径区域根部存在沿周向分布且长短不一的微裂纹,机械加工导致阀盖内表面应力状态改变,在高温、高压水环境作用下,阀盖内表面的钝化膜破裂,加速了裂纹的萌生与扩展,最终导致阀盖发生应力腐蚀开裂.
A leakage incident occurred at the isolation valve cover of a nuclear power unit's sampling system.The causes of the valve cover leakage were analyzed using macroscopic observation,penetrant testing,chemical composition analysis,mechanical property testing,scanning electron microscopy and energy spectrum analysis,and metallographic examination.The results show that there were two axial cracks on the inner surface of the valve cover,as well as circumferentially distributed microcracks of varying lengths at the root of the valve cover diameter transition area.Mechanical processing altered the stress state of the valve cover's inner surface,leading to the rupture of the passive film under high-temperature and high-pressure water conditions,which accelerated crack initiation and propagation,ultimately resulting in stress corrosion cracking of the valve cover.
辛虹阳;张伟;余飞扬;雷阳;郑霄;滕常青;谷昊
中国核动力研究设计院第一研究所,成都 610000中国核动力研究设计院第一研究所,成都 610000中国核动力研究设计院第一研究所,成都 610000中国核动力研究设计院第一研究所,成都 610000中国核动力研究设计院第一研究所,成都 610000中国核动力研究设计院第一研究所,成都 610000辽宁红沿河核电有限公司,大连 116000
通用工业技术
阀盖泄漏变径区域应力腐蚀开裂显微组织
valve coverleakagediameter transition areastress corrosion crackingmicrostructure