双相不锈钢加药泵叶轮腐蚀的原因OA
Reasons for corrosion of impeller in duplex stainless steel dosing pump
某电厂冲击加药泵叶轮发生严重腐蚀现象.采用宏观观察、化学成分分析、金相检验、力学性能测试、扫描电镜及能谱分析等方法对该叶轮腐蚀的原因进行分析.结果表明:叶轮的化学成分和断后伸长率均不满足标准要求,组织中含有大量的σ偏析相,导致材料的耐腐蚀性能显著降低,材料的韧性较差;同时,叶轮材料的腐蚀速率是304不锈钢的3.9倍,叶轮长期在含氯介质中运行,材料晶界位置成为点蚀起源,腐蚀沿纵深向发展,最终造成叶轮腐蚀.
Severe corrosion occurred on the impeller of the impact dosing pump in a certain power plant.The reasons for the corrosion of the impeller were analyzed using macroscopic observation,chemical composition analysis,metallographic examination,mechanical property testing,scanning electron microscopy and energy spectrum analysis.The results show that the chemical composition and elongation after fracture of the impeller did not meet the standard requirements,and there were a large number of σ segregation phases in the microstructure,which resulted in a significant decrease in the corrosion resistance of the material and poor toughness.At the same time,the corrosion rate of the impeller material was 3.9 times that of 304 stainless steel.The impeller operated in a chlorine containing medium for a long time,and the grain boundary position of the material became the source of pitting corrosion.Corrosion developed along the depth,ultimately causing impeller corrosion.
杨添;陶钧;赵传礼;张云乾;唐耀波
中核运维技术有限公司,杭州 311200中核运维技术有限公司,杭州 311200中核运维技术有限公司,杭州 311200中核运维技术有限公司,杭州 311200中核运维技术有限公司,杭州 311200
通用工业技术
双相不锈钢叶轮σ相腐蚀显微组织
duplex stainless steelimpellerσ phasecorrosionmicrostructure
《理化检验-物理分册》 2026 (8)
1-4,4