为评估预压碟簧自复位装配式RC框架梁柱节点的抗震性能,针对该类梁柱节点进行拟静力试验.设计中梁柱节点采用碟簧自复位装置提供复位力,利用转动摩擦阻尼器耗散地震能量,通过摩擦型高强螺栓连接完成装配.主要设计参数有复位率α和弯矩调控系数β,取值范围分别为1.00~2.38和1.2~2.34.共制作4个梁柱节点,验证梁柱节点构造形式的可行性,研究梁柱节点在低周往复荷载作用下的滞回性能及耗能机理,量化评价其自复位能力.试验结果表明:梁柱节点力-位移曲线呈现旗帜形滞回特征;设置转动摩擦阻尼器能够使梁柱节点形成集中耗能机制,保护梁柱构件免受损伤;碟簧自复位装置可有效控制该类梁柱节点的残余变形,提升可恢复功能;转动摩擦阻尼器的耗能机理源于接触面间的黏着效应与犁沟效应;控制复位率α为2.38、弯矩调控系数β为1.42,该类梁柱节点加载位移角达到0.03 rad时,可控塑性铰转角可达0.028 rad,残余位移角仍可控制在0.002 rad内,梁柱构件可处于无损伤或低损伤状态.

To assess the seismic performance of prefabricated RC frame beam-column joints with pre-pressed disc spring self-centering devices,a quasi-static test was performed on the joint.The joint adopts disc spring self-centering devices to provide restoring force,employs rotational friction damper to dissipate seismic energy,and is assembled through friction-type high-strength bolt connections.The main design parameters are the self-centering ratio α and the moment regulation coefficient β,with value ranges of 1.00-2.38 and 1.2-2.34,respectively.A total of four beam-column joints were fabricated to verify the feasibility of the joint configuration,investigate the hysteretic performance and energy dissipation mechanism of the joints under low-cycle reversed loading,and quantitatively evaluate their self-centering capability.Test results demonstrate that the force-displacement curves of the joints display flag-shaped hysteretic behavior.The installation of rotational friction dampers enables the beam-column joint to form a concentrated energy dissipation mechanism,thereby protecting the beam and column components from damage.The disc spring self-centering device effectively controls the residual deformation of the joint and enhance its recoverable function.The energy dissipation mechanism of rotational friction dampers originates from the adhesion effect and the plowing effect between the contact surfaces.With the self-centering ratio α controlled at 2.38 and the moment regulation coefficient β at 1.42,when the loading drift ratio of this type of beam-column joint reaches 0.03 rad,the controllable plastic hinge rotation can reach 0.028 rad,while the residual drift ratio can still be controlled within 0.002 rad.The beam and column components can remain in a damage-free or low-damage state.

马立成;史庆轩;马占武;车佳玲;章毅;马肖彤;王秋维

北方民族大学土木工程学院,宁夏银川 750021西安建筑科技大学土木工程学院,陕西西安 710055||西安建筑科技大学结构工程与抗震教育部重点实验室,陕西西安 710055北方民族大学土木工程学院,宁夏银川 750021宁夏大学土木与水利工程学院,宁夏银川 750021银川市规划建筑设计院工程承包咨询有限公司,宁夏银川 750001北方民族大学土木工程学院,宁夏银川 750021西安建筑科技大学土木工程学院,陕西西安 710055||西安建筑科技大学结构工程与抗震教育部重点实验室,陕西西安 710055

建筑与水利

钢筋混凝土框架结构装配式梁柱节点自复位组合碟簧转动摩擦阻尼器拟静力试验抗震性能

RC frame structureassembled beam-to-column jointself-centeringcombined disc springsrotational friction damperquasi-static testseismic performance