首页|期刊导航|节能|基于深度调峰工况下节能型三维肋片式空预器的应用

基于深度调峰工况下节能型三维肋片式空预器的应用OA

Application of energy-saving three-dimensional ribbed air preheater under deep peak-regulating conditions

中文摘要英文摘要

在新能源大规模并网背景下,燃煤机组深度调峰运行成为常态,传统空气预热器在低负荷工况下易出现积灰、磨损、硫酸氢铵沉积及漏风率高等问题,影响机组的安全性与经济性.以某循环流化床锅炉机组为研究对象,针对其空预器运行中存在的问题,提出并实施三维肋片式空预器节能改造方案,并采用立式结构布置、三维肋片强化换热技术及模块化高温气流冲洗系统,优化烟气流场分布与换热过程.结果表明,改造后排烟温度降至120℃以下,空预器漏风率降至3%以下,供电煤耗下降约7.34 g/kWh,机组深度调峰适应能力及运行经济性提升.

Under the background of large-scale integration of new energy sources,deep peak-load operation of coal-fired units has become the norm.Traditional air preheaters are prone to problems such as ash accumulation,wear,deposition of ammonium sulfate hydrogen,and leakage rate under low-load conditions,which affect the safety and economy of the units.Taking a certain circulating fluidized bed boiler unit as the research object,in response to the problems existing in the operation of its air preheater,a three-dimensional ribbed air preheater energy-saving renovation scheme is proposed and implemented.The scheme adopted a vertical structure layout,three-dimensional ribbed enhanced heat transfer technology,and modular high-temperature gas flow flushing system to optimize the distribution of the flue gas flow field and the heat transfer process.The results show that after the renovation,the flue gas outlet temperature dropped to below 120℃,the leakage rate of the air preheater decreased to below 3%,the power consumption decreased by approximately 7.34 g/kWh,and the adaptability of the unit for deep peak-load operation and the operational economy are improved.

刘斌;吴浪

国能亿利能源有限责任公司电厂,内蒙古 鄂尔多斯 014300国能亿利能源有限责任公司电厂,内蒙古 鄂尔多斯 014300

信息技术与安全科学

循环流化床锅炉三维肋片管空气预热器深度调峰节能改造

circulating fluidized bed boilerthree-dimensional ribbed tubeair preheaterdeep peak shavingenergy-saving renovation

《节能》 2026 (8)

27-31,5

10.3969/j.issn.1004-7948.2026.08.006

评论