建筑玻璃幕墙与主体结构连接的火灾危险性分析OA
Fire Risk Analysis of the Connections between Building Glass Curtain Walls and Main Structures
本研究以玻璃幕墙与主体结构的连接为研究对象,采用Pyrosim软件,基于t²非稳态火灾增长模型,对行政办公室、综合办公室、商场服装店、宾馆客房和住宅卧室五种典型建筑空间进行火灾全过程数值模拟,获得幕墙连接处的温度场;进而利用ABAQUS有限元软件对最危险火灾场景下混凝土基体和连接件内部温度进行模拟,考虑高温下材料强度劣化,验算幕墙连接处钢角码、螺栓、埋件(爪式、槽式、化学锚栓)及焊缝的承载力.结果表明:火灾下防火封堵处的温度达到600℃以上,目前工程上普遍采用的防火封堵(由镀锌钢板和岩棉组成)在火灾下存在脱落风险;外露的连接部件(钢角码、螺栓、焊缝等)及化学锚栓埋件火灾下的承载力不满足要求,而爪形和槽式预埋件的承载力基本能满足要求.建议工程中应优先采用预埋式连接,并应提高防火封堵的耐火性能、增设连接件的防火保护、适当提高连接件承载力冗余度,以确保火灾下幕墙连接的安全性.
This study investigates the fire performance of connections between curtain walls and primary structures.Utilizing Pyrosim software and the t² quasi-steady fire growth model,numerical simulations of the full fire development process were conducted across five representative architectural spaces:administrative offices,general offices,retail apparel stores,hotel rooms,and residential bedrooms,to characterize the temperature field at the connection interface.Subsequently,ABAQUS finite element analysis was employed to simulate the internal temperature profiles of concrete substrates and connectors under the most severe fire scenario.Accounting for high-temperature-induced material degradation,the load-bearing capacities of critical connection components were evaluated,including steel angle brackets,bolts,embedded parts(cast-in claw,cast-in channel,and chemical anchors),and welds.Results indicate that temperatures at fire-stop seals exceed 600℃during fire exposure,revealing a detachment risk in conventional seal assemblies comprising galvanized steel sheets and rock wool.Exposed components(e.g.,steel brackets,bolts,welds)and chemical anchor systems fail to meet fire-resistance requirements,whereas cast-in claw and channel embedded parts demonstrate adequate capacity.The study recommends prioritizing cast-in embedded systems in design,enhancing the fire resistance of fire-stop seals,applying supplementary fire protection to connection elements,and incorporating appropriate capacity redundancy to ensure structural integrity under fire conditions.
张慧勤;胡克旭;李宗沅;白雪
浙江正泰新能源开发有限公司,杭州 310053同济大学土木工程学院,上海 200092同济大学土木工程学院,上海 200092上海城建职业学院,上海 200438
建筑与水利
玻璃幕墙火灾模拟连接件承载力火灾危险性
glass curtain wallfire simulationconnectorbearing capacityfire risk
《结构工程师》 2026 (4)
39-47,9
评论