高预拉力单边螺栓钢管混凝土柱-梁节点的数值分析OA

Numerical Analysis of CFST Columns to Beams Connection with High Preload Novel Slip-Critical Blind Bolts

中文摘要英文摘要

为了研究采用新型单边螺栓SCBB与外伸端板连接的方钢管混凝土柱-梁节点的性能,利用ABAQUS有限元软件建立了已进行过试验的该节点的数值计算模型,分析了节点的破坏模式、滞回曲线、极限承载力、弹性刚度和耗能能力,并与试验结果进行了对比,验证了数值计算模型的准确性.运用此模型就钢梁截面宽厚比、混凝土楼板内的钢筋分布和配筋率对节点受力性能的影响进行了讨论.研究结果表明,梁截面板件宽厚比满足S1级和S2级时均可用作耗能梁构件,混凝土楼板内不同的钢筋分布和不同的配筋率对节点的极限承载力和弹性刚度影响较小.

To investigate the behavior of bolted end-plate connections to concrete-filled steel tubular(CFST)columns utilizing a novel slip-critical blind bolt(SCBB),finite element(FE)models were developed using ABAQUS.Model parameters were calibrated based on existing joint experiments.The FE models were validated against test results through comparisons of failure modes,hysteretic curves,ultimate bearing capacity,elastic stiffness,and energy dissipation capacity.Furthermore,parametric analysis examined the influence of the beam flange width-to-thickness ratio,reinforcement layout,and reinforcement ratio of the reinforced concrete(RC)slab on joint mechanical properties.Results indicate that beams complying with the S1 and S2 width-to-thickness ratio criteria are suitable for seismic energy dissipation.Variations in reinforcement layout and ratio exerted marginal effects on the ultimate bearing capacity and elastic stiffness of the joints.

焦伟丰;范斌;李鹏;张妙;王伟;施晨

中建一局集团建设发展有限公司,北京 100102平湖城市建设投资有限公司,嘉兴 314000中建一局集团建设发展有限公司,北京 100102中建一局集团建设发展有限公司,北京 100102同济大学土木工程防灾减灾全国重点实验室,上海 200092平湖城市建设投资有限公司,嘉兴 314000

建筑与水利

单边螺栓钢管混凝土柱有限元模型参数分析钢筋混凝土楼板

blind boltCFST columnFEMparameter analysisRC slab

《结构工程师》 2026 (4)

10-19,10

10.15935/j.cnki.jggcs.202604.0002

评论