腔内心电图定位技术和X线摄片应用于新生儿脐静脉置管中的效果对比OA
Comparison of the effects of intracavitary electrocardiogram localization technology and X-ray radiography in neonatal umbilical venous catheterization
目的 探讨腔内心电图定位技术和X线摄片技术在新生儿脐静脉置管中应用效果.方法 选取河南中医药大学第五临床医学院(郑州人民医院)新生儿重症监护室2023年1月—2025年6月间收治的88例拟进行脐静脉置管的新生儿,随机分为两组.对照组患儿使用常规置管后行X线摄片检测,观察组患儿联合使用腔内心电图定位技术,两组患儿置管后均观察1周.比较两组患儿脐静脉置管时长,首次置管成功率,导管尖端位置精准率;观察期间置管相关并发症发生率.结果 两组患儿均完成脐静脉置管,观察组患儿脐静脉置管时长为(12.82±2.49)min,低于对照组患儿(15.68±2.67)min(P<0.05);观察组患儿首次置管成功率为93.18%(41/44),高于对照组患儿77.27%(34/44)(P<0.05).置管完成后行超声检测,对照组患儿置管准确率为81.82%(36/44),低于观察组患儿95.45%(42/44)(P<0.05).两组患儿均有发生置管相关并发症,观察组患儿并发症总发生率4.55%(2/44)低于对照组患儿20.45%(9/44)(P<0.05).结论 腔内心电图定位技术联合X线摄片可提升脐静脉置管准确率及置管速度,提升一次置管成功率;同时可减少导管相关并发症发生率.
Objective To explore the application effects of intracavitary electrocardiogram localization technology and X-ray radiography technology in neonatal umbilical venous catheterization.Methods Eighty-eight newborns admitted to the Neonatal Intensive Care Unit of the Fifth Clinical Medical College of Henan University of Chinese Medicine(Zhengzhou People's Hospital)and scheduled for umbilical venous catheterization between January 2023 and June 2025 were enrolled and randomly assigned into two groups.The control group received conventional catheterization followed by X-ray imaging,while the observation group received intracavitary electrocardiogram localization combined with X-ray radiography.Both groups were observed for one week after catheterization.The duration of umbilical venous catheterization,the success rate of the first catheterization,and the accuracy of catheter tip placement were compared between the two groups.The incidence of catheterization-related complications during the observation period was also observed.Results Both groups of children completed umbilical venous catheterization.The duration of umbilical venous catheterization in the observation group was(12.82±2.49)minutes,which was shorter than that in the control group with(15.68±2.67)minutes(P<0.05).The success rate of initial catheterization in the observation group was 93.18%(41/44),which was higher than that in the control group(77.27%[34/44],P<0.05).After catheterization,ultrasound examination was performed.The accuracy rate of catheterization in the control group was 81.82%(36/44),which was lower than that in the observation group(95.45%[42/44],P<0.05).Both groups of children experienced catheterization-related complications.The total incidence rate of complications in the observation group was 4.55%(2/44),which was lower than that in the control group(20.45%[9/44],P<0.05).Conclusions The combination of intracavitary electrocardiogram localization technology and X-ray radiography can enhance the accuracy and speed of umbilical venous catheterization,improve the success rate of catheterization in one attempt,and reduce the incidence of catheter-related complications.
王文静;许晴;王丽
河南中医药大学第五临床医学院(郑州人民医院)新生儿重症监护室(河南 郑州 450000)河南中医药大学第五临床医学院(郑州人民医院)新生儿重症监护室(河南 郑州 450000)河南中医药大学第五临床医学院(郑州人民医院)新生儿重症监护室(河南 郑州 450000)
新生儿脐静脉置管腔内心电图定位技术X线摄片导管尖端定位
newbornumbilical venous catheterizationintracavitary electrocardiogram localization techniqueX-ray radiographycatheter tip localization
《广州医药》 2026 (8)
990-995,6
评论