浅谈ERCP取石操作中一次性耗材的设计缺陷及改进创新OA
Brief discussion on the design defects and improvement innovations of disposable consumables in ERCP stone extraction
经内镜逆行胰胆管造影(ERCP)是目前治疗胆总管结石的首选方案之一,具有创伤小、恢复快、可重复性强等优点.经过50多年的发展,ERCP操作技术日益成熟,取石成功率显著提高,并发症发生率显著降低.然而,ERCP相关的选择性胆管插管失败、取石失败、导丝穿孔、支架移位等事件仍时有发生,这除了与医师的操作技术水平有关之外,还与ERCP操作过程中一次性耗材存在设计缺陷、产品更新换代速度慢有一定的关系.本文总结我们团队采取ERCP技术治疗胆总管结石二十余年的临床经验,结合国内外相关文献,对进口和国产一次性耗材存在的设计缺陷进行论述,比如鼻吸氧管只能给鼻腔供氧,但是鼻咽部狭窄或堵塞患者佩戴鼻吸氧管容易发生低氧血症;弓状乳头括约肌切开刀的刀丝缺少绝缘保护,可引起十二指肠皱襞的副损伤;乳头括约肌切开刀的鞘管只有一个导丝通道,采取双导丝法进行困难性胆管插管时,需要退出乳头括约肌切开刀;导丝只有一个软性头端,困难性胆管插管可能需要使用多根导丝;导丝表面的斑马纹有助于显示导丝的移动,但是不能确定导丝置入的深度;球囊扩张导管需全程通过导丝,不能进行快速交换;通过取石球囊导管可以向球囊远端胆管注入造影剂,但是球囊近端胆管结石往往显示不清;取石网篮鞘管较粗,细径胆总管结石容易被推入肝内胆管;无引导头的取石网篮鞘管容易误入胰管内,也难以置入胆囊管或目标肝内胆管;碎石网篮在十二指肠乳头的通过性差,坚硬的小结石碎石效率低,一次碎石后网篮钢丝容易形变;激光或液电碎石只能在子镜直视下进行,不能在X线下完成;线形胆管支架取出时,远端侧翼容易刮伤十二指肠乳头;单猪尾胰管支架释放难度高,近端移位的单猪尾胰管支架取出难度更大;全覆膜金属支架置入后会破坏胆道密闭性,容易发生肠胆反流;鼻胆管的单猪尾襻只能在扩张的胆管内成襻,鼻胆管取出过程中单猪尾襻或直头均容易刮伤十二指肠乳头.我们对目前的一次性耗材进行了改进,设计了一体式供氧口垫、多模式口鼻供氧口垫,双导丝乳头括约肌切开刀、快速交换乳头括约肌切开刀,双头斑马导丝、斑马标记定位导丝,快速交换球囊扩张导管,快速交换双向注射取石球囊,乳头括约肌切开刀辅助取石网篮、内镜导丝取石网篮,多功能碎石/取石网篮,灯笼状胆管支架、快速交换胆管支架,单猪尾带侧翼胰管支架,带长回收线的全覆膜金属支架,双猪尾胆囊支架,灯笼状α形鼻胆引流管,以及系列胆道镜透明帽等产品,上述耗材的创新设计不仅能提高ERCP取石操作成功率,降低并发症发生率,还能增加国产耗材的竞争力.
Endoscopic retrograde cholangiopancreatography(ERCP)is one of the most preferred treatment options for common bile duct stones,with advantages of minimally invasive,fast recovery,and strong reproducibility.After more than 50 years of development,ERCP technology has become increasingly mature,the success rate of stone extraction has significantly increased,and the incidence rate of complications has significantly decreased.However,ERCP-related events such as selective biliary catheterization failure,stone extraction failure,guidewire perforation,and stent displacement still occur occasionally.In addition to the proficiency of physicians,the design defects of disposable consumables and slow product updates during ERCP procedures are also related to certain factors.This article summarizes our team's clinical experience of using ERCP technology to treat common bile duct stones for more than 20 years.Based on relevant literature at home and abroad,this article discusses the design defects of imported and domestic disposable consumables.For example,nasal oxygen tubes can only provide oxygen to nasal cavity,but patients with nasopharyngeal stenosis or blockage who wear nasal oxygen tubes for oxygen supply are prone to hypoxemia.The lack of insulation protection for guidewire of arciform sphincterotome can cause secondary damage to duodenal folds.The sphincterotome has only one guidewire channel,and double-guidewire method is used for difficult biliary cannulation,which requiring withdrawal of sphincterotome.Balloon dilation catheters need to pass through guidewire throughout the entire process and cannot be exchanged quickly.The guidewire has only one soft tip,and difficult biliary cannulation may require multiple guidewires.The zebra stripes on surface of guidewire help to indicate its movement,but cannot determine its insertion depth.Contrast agent can be injected into the distal bile duct of balloon through a stone extraction balloon catheter,but the proximal bile duct stones are often not clearly visible.The sheath tube of stone extraction basket is relatively thick,and stones in small diameter common bile duct are easily pushed into intrahepatic bile duct.The stone extraction basket sheath without a guiding head is prone to accidentally entering pancreatic duct and is difficult to insert into cystic duct or target intrahepatic bile duct.The gravel basket is difficult to pass through duodenal papilla,the efficiency of crushing hard small stones is low,and the steel wire of basket is prone to deformation.Laser or liquid electric lithotripsy can only be performed under direct view of a microscope and cannot be completed under X-ray.When the linear bile duct stent is removed,the distal flank is prone to scratching duodenal papilla.The difficulty of releasing a single-pigtail pancreatic duct stent is high,and the difficulty of removing a single-pigtail pancreatic duct stent with proximal displacement is even greater.The placement of a fully covered biliary metal stent can damage airtightness of bile duct and easily lead to intestinal bile reflux.The single-pigtail loop of nasobiliary drainage tube can only form a loop within dilated bile duct.During the process of removing nasobiliary drainage tube,the single-pigtail loop or straight head is prone to scratching duodenal papilla.We have made many improvements and designed many innovative disposable products,such as integrated oxygen supply mouth guard,multi-mode oral-nasal oxygen supply mouth guard;double-guidewire sphincterotome,rapid exchange sphincterotome;double-headed zebra guidewire,zebra marker positioning guidewire;rapid exchange balloon dilation catheter;rapid exchange bidirectional injection stone extraction balloon;sphincterotome-assisted stone extraction basket,endoscopic guidewire stone extraction basket;multi-function stone gravel and extraction basket;lantern-shaped bile duct stent,rapid exchange bile duct stent;single-pigtail with side wing pancreatic duct stent;fully covered metal stent with long recycling line;double-pigtail gallbladder stent;lantern-shaped alpha-shaped nasobiliary drainage tube,and series of transparent caps for cholangioscopy.The innovative design of above-mentioned consumables can not only improve the success rate of ERCP stone extraction and reduce the incidence rate of complications,but also increase the competitiveness of domestic consumables.
张诚;张桂信;杨玉龙
大连医科大学附属第二医院肝胆胰外科,辽宁 大连 116021||同济大学附属东方医院胆石病中心,上海 200120大连医科大学附属第二医院肝胆胰外科,辽宁 大连 116021同济大学附属东方医院胆石病中心,上海 200120
医药卫生
内镜逆行胰胆管造影胆总管结石一次性耗材设计缺陷改进和创新专利成果转化
endoscopic retrograde cholangiopancreatographycommon bile duct stonesdisposable consumablesdesign defectimprovement and innovationpatents transformation
《肝胆胰外科杂志》 2026 (10)
685-698,705,15
上海市浦东新区卫生系统重点专科项目(PWZzk2022-17).
评论