环境温度对特高压换流变阀侧套管芯体表面电荷及体电荷的影响OA
Influence of Ambient Temperature on Surface and Volume Charge in the UHV Converter Transformer Valve-side Bushing Core
特高压换流变阀侧套管是直流输电系统的核心设备,其安全稳定运行对于直流输电通道的安全至关重要.为评估环境温度变化对表面电荷的影响,通过三维电磁-热-流耦合方法,计算了换流变阀侧套管在-20~60 ℃环境温度下的热场分布.通过测量阀侧套管芯体环氧浸纸材料电导,建立了体电导与表面电导随温度的变化关系,计算了阀侧套管在不同环境温度下的芯体表面电荷与体电荷分布.研究结果表明,环境温度的降低会增大芯体径向电场及芯体表面法向电场.低温导致环氧浸纸材料的深陷阱密度增加,载流子不易脱陷,导致芯体表面电荷密度及体电荷密度幅值增大.环境温度从20 ℃降至-20 ℃,气侧芯体最大体电荷密度增大47.5%,最大径向电场强度增大21.1%,气侧法向电场增大10.7%.环境温度的降低在一定程度上畸变套管内部电场分布,增加了绝缘失效风险.
The valve-side bushing is a core component of DC transmission systems,and its safe and stable operation is crucial for channel security.To evaluate the influence of ambient temperature variation on the charge at the surface,this paper computes the thermal field distribution from-20 ℃ to 60℃.By measuring the conductivity of the epoxy-impregnated paper material of the valve-side bushing core,the relationship between bulk conductivity and surface conductivity with temperature is established.The surface charge and bulk charge distributions on the core under different ambient temperatures are calculated.The results show that a decrease in ambient temperature increases the radial electric field of the core and the normal electric field on the core surface.Low temperature leads to an increase in deep trap den-sity of the epoxy-impregnated paper material,making it difficult for carriers to detrap,thereby increasing the amplitude of surface charge density and bulk charge density.When the ambient temperature drops from 20℃ to-20℃,the maxi-mum bulk charge density on the air-side core increases by 47.5%,the maximum radial electric field intensity increases by 21.1%,and the air-side normal electric field increases by 10.7%.The reduction in ambient temperature distorts the inter-nal electric field distribution of the bushing to some extent,increasing the risk of insulation failure.
李杨;王青于;刘则希;刘鹏;马博;陈晓东
电工材料电气绝缘全国重点实验室(西安交通大学),西安 710049电工材料电气绝缘全国重点实验室(西安交通大学),西安 710049电工材料电气绝缘全国重点实验室(西安交通大学),西安 710049电工材料电气绝缘全国重点实验室(西安交通大学),西安 710049西安西电高压套管有限公司,西安 710077西安西电高压套管有限公司,西安 710077
阀侧套管电热耦合表面电荷环境温度深浅陷阱
valve-side bushingelectro-thermal couplingsurface chargeambient temperaturedeep and shallow traps
《高电压技术》 2026 (8)
3524-3536,13
智能电网国家科技重大专项(2030)(2026ZD0813200).Project supported by Smart Gird-national Science and Technology Major Project(2026ZD0813200).