首页|期刊导航|分子影像学杂志|前置混合双流团注追踪法在双源CT肺动脉血管造影中的可行性分析

前置混合双流团注追踪法在双源CT肺动脉血管造影中的可行性分析OA

Feasibility analysis of pre-dual-flow injection bolus tracking protocol for dual-source CT pulmonary angiography

中文摘要英文摘要

目的 探讨自由呼吸状态下前置混合双流团注追踪法在双源CT能谱成像方式肺动脉血管造影(CTPA)中的可行性,评估其图像质量.方法 回顾性分析2025年3~12月在南方医科大学南方医院行肺动脉血管CTA检查的100例患者,分为前置混合双流团注追踪法(A组)和小剂量团注测试法(B组),50例/组.对2组图像的血管内CT值、信噪比(SNR)、对比噪声比(CNR)以及辐射剂量进行客观分析,从肺动脉充盈度、肺动静脉分离度、上腔静脉硬化伪影、呼吸运动伪影4个方面做主观质量评价.结果 A组CT值在右肺基底动脉干、左肺下叶动脉、右肺后底段A10、左肺后底段A10显著高于B组,A组上腔静脉CT值低于B组(P<0.05),A组SNR、CNR在左肺下叶动脉、右肺后底段A10、左肺后底段A10高于B组(P<0.05);主观质量评分中,A组上腔静脉硬化伪影低于B组(P<0.05).结论 自由呼吸状态下低对比剂用量的前置混合双流团注追踪法在双源CT CTPA中在降低上腔静脉伪影和保证图像质量方面具有显著的优势.

Objective To investigate the feasibility of pre-dual-flow injection bolus tracking protocol with free-breathing for dual-source CT spectral pulmonary angiography(CTPA)and assess its image quality.Methods A retrospective analysis was conducted on 100 patients who underwent CTPA at Nanfang Hospital of Southern Medical University from March to December 2025.The patients were divided into pre-dual-flow injection bolus tracking protocol(group A,n=50)or test bolus protocol(group B,n=50).The CT values,signal-to-noise ratio(SNR),contrast-to-noise ratio(CNR)and radiation dose were compared between the two groups in objective analysis.The vascular filling,arteriovenous separation,beam hardening artifact of SVC and respiratory artefact were scored in subjective analysis.Results Compared with Group B,the CT values were significantly higher in the right pulmonary basal artery trunk,left lower artery,right posterior basal(A10),and left posterior basal(A10)in group A,while the CT value of the superior vena cava(SVC)was significantly lower in group A(P<0.05).The SNR and CNR were significantly higher in the left lower artery,right posterior basal(A10)and left posterior basal(A10)in group A(P<0.05).The beam hardening artefact of SVC was significantly lower in group A(P<0.05).Conclusion The pre-dual-flow injection bolus tracking protocol with free-breathing and combined with lower volume of contrast medium has significant advantages in reducing beam hardening artefact of SVC and ensuring image quality for dual-source CTPA.

王君玲;蹇明爵;周建伟;胡罢生;余泽君;陈斌

南方医科大学南方医院医学影像中心,广东 广州 510515南方医科大学南方医院医学影像中心,广东 广州 510515南方医科大学南方医院医学影像中心,广东 广州 510515南方医科大学南方医院医学影像中心,广东 广州 510515南方医科大学南方医院医学影像中心,广东 广州 510515南方医科大学南方医院医学影像中心,广东 广州 510515

前置混合双流团注追踪法小剂量团注测试法双源CT能谱成像方式肺动脉血管造影自由呼吸

pre-dual-flow injection bolus trackingtest bolusdual-source CT spectral pulmonary angiographyfree-breathing

《分子影像学杂志》 2026 (8)

1037-1043,7

广东省自然科学基金面上项目(2026A1515010503)

10.12122/j.issn.1674-4500.2026.08.08

评论