首页|期刊导航|分析测试学报|加速溶剂萃取/气相色谱-三重四极杆质谱法测定大气中苯并三唑类紫外吸收剂

加速溶剂萃取/气相色谱-三重四极杆质谱法测定大气中苯并三唑类紫外吸收剂OA

Determination of Benzotriazole Ultraviolet Absorbers in the Ambient Atmosphere by Accelerated Solvent Extraction/Gas Chromatography-Triple Quadrupole Mass Spectrometry

中文摘要英文摘要

该研究建立了一种灵敏、可靠、可同时测定大气中颗粒相与气相苯并三唑类紫外吸收剂(BUVs)的监测方法,目标组分包括UV-320、UV-326、UV-327和UV-328四种常见BUVs.使用大流量空气采样器,分别用石英滤膜、聚氨酯泡沫/XAD-2树脂采集颗粒相和气相样品.样品经加速溶剂提取、硅胶柱净化,使用气相色谱-三重四极杆质谱测定.4种目标组分在1~200 ng/mL范围内呈良好线性关系,相关系数(r)均大于0.999,检出限为0.4~0.5 pg/m3,定量下限为1.6~2.0pg/m3.石英滤膜、聚氨酯泡沫和XAD-2树脂空白加标样品中目标物的回收率分别为83.0%~103%、74.9%~108%和83.4%~96.0%,相对标准偏差(RSD)不大于10%.使用该方法测定实际大气样品中BUVs,检出了 UV-326和UV-328,浓度为0.9~6.8 pg/m3,UV-320和UV-327 均未检出.该方法灵敏度好且准确性高,满足大气样品中痕量BUVs的分析需求,可为深入研究大气中BUVs的环境行为及生态风险提供可靠的分析工具.

In this study,a sensitive and reliable analytical method was established for the simultane-ous determination of gaseous and particulate benzotriazole ultraviolet absorbers(BUVs)in ambient air.The target analytes included four common BUVs:UV-320,UV-326,UV-327,and UV-328.Specifically,a high-volume air sampler was used to collect gaseous and particulate BUVs sepa-rately,with quartz fiber filters(QFF)for particulate phase and polyurethane foam(PUF)/XAD-2 res-in for gaseous phase.Air samples were extracted by accelerated solvent extraction,purified by silica cartridges,and analyzed by gas chromatography-triple quadrupole mass spectrometry.Method vali-dation experiments were carried out to evaluate the performance of the established method,and the results showed that the four target compounds exhibited a good linear relationship in the concentration range of 1-200 ng/mL,with correlation coefficients(r)all greater than 0.999.The method detection limits ranged from 0.4 to 0.5 pg/m3,and the quantitation limits ranged from 1.6 to 2.0 ng/m3,which was sufficiently low to detect trace levels of BUVs in ambient air.The recoveries of the target analytes in QFF,PUF,and XAD-2 samples were 83.0%-103%,74.9%-108%,83.4%-96.0%,and the relative standard deviations(RSDs)were less than 10%for all target analytes,respectively.The method was used to monitor BUVs in ambient air samples of Beijing,and UV-326 and UV-328 were detected with concentration range of 0.9-6.8 pg/m3,while UV-320 and UV-327 were not de-tected in any samples.The established method is highly sensitive and accurate,which can fully meet the monitoring requirements for trace BUVs in the ambient atmosphere.It not only provides a reliable analytical tool for further in-depth research on the environmental behavior and ecological risks of BU-Vs in the atmospheric environment but also lays a solid foundation for the environmental monitoring and risk control of BUVs.

刘梦;杜涛;刘金林;刘承友;唐晗昱;张利飞;张烃

陕西省环境介质痕量污染物监测预警重点实验室,陕西 西安 710054||国家环境分析测试中心,北京 100029||生态环境部二(噁)英污染控制重点实验室,北京 100029陕西省环境介质痕量污染物监测预警重点实验室,陕西 西安 710054国家环境分析测试中心,北京 100029||生态环境部二(噁)英污染控制重点实验室,北京 100029国家环境分析测试中心,北京 100029||生态环境部二(噁)英污染控制重点实验室,北京 100029国家环境分析测试中心,北京 100029||生态环境部二(噁)英污染控制重点实验室,北京 100029国家环境分析测试中心,北京 100029||生态环境部二(噁)英污染控制重点实验室,北京 100029国家环境分析测试中心,北京 100029||生态环境部二(噁)英污染控制重点实验室,北京 100029

化学化工

苯并三唑类紫外吸收剂大气监测气相色谱-三重四极杆质谱加速溶剂萃取

benzotriazoleultraviolet absorbersair monitoringgas chromatography-triple quad-rupole mass spectrometryaccelerated solvent extraction

《分析测试学报》 2026 (9)

1910-1917,8

京津冀环境综合治理国家科技重大专项资助(2025ZD1203300)陕西省环境介质痕量污染物监测预警重点实验室开放基金项目(SHJKFJJ-YB-202402)

10.12452/j.fxcsxb.26032701

评论