3D打印导板辅助内侧单髁置换术后早期步态改善但伸膝功能仍不全:一项观察性自身对照研究OA

Early gait improvement but persistent knee extension deficit after medial unicompartmental knee arthroplasty assisted by 3D-printed patient-specific instrumentation:an observational self-controlled study

中文摘要英文摘要

目的 内侧单髁置换术(unicompartmental knee arthroplasty,UKA)是治疗膝关节内侧间室骨关节炎的有效保膝术式,3D打印导板辅助技术可提升假体安放精准度,但术后功能恢复尚缺乏客观量化证据,且缺乏与正常人群的对比研究.本研究旨在通过三维步态分析,评估导板辅助内侧UKA术后早期膝关节矢状面运动学恢复规律,明确术后步态异常的具体表现.方法 采用观察性自身对照(患/健侧)研究设计方案,纳入2024年11月至2025年5月于西南医院创伤关节外科行3D打印导板辅助内侧UKA的24例(25侧膝盖)患者为观察组,选择15侧无症状对侧膝盖作为对照组.分别于术前及术后3个月进行采集髋-膝-踝(hip-knee-ankle,HKA)角、美国西部Ontario与McMaster大学骨关节炎指数(Western Ontario and McMaster University Osteoarthritis Index,WOMAC)评分及矢状面膝关节运动学参数,作组内(观察组术前与术后比较)及组间(观察组术前、术后分别与对照组比较)对比分析.结果 观察组患者随访时间为2.90~6.73个月,平均(4.15±1.12)个月.观察组术后WOMAC评分(0.92±1.44 vs 12.76±3.94)、僵硬评分(0.88±1.09 vs 2.84±2.34)、功能评分(2.72±3.02 vs 47.80±12.08)较术前均显著改善(P<0.001);观察组术后HKA角较术前显著增加[(177.14±2.48)vs(171.44±4.21)°,P<0.001],内翻畸形明显矫正,较对照组[(177.02±3.11)°]无统计学差异.观察组术后摆动相最大屈曲角度[(60.51±5.20)vs(47.13±12.68)°,P<0.001]与术前相比显著增加,承重反应期占比(10.36%±3.32%vs 15.84%±11.43%,P=0.029)与术前相比显著缩短,与对照组比较无统计学差异;观察组术后支撑相最小屈曲角度[(10.63±5.85)vs(6.14±5.04)°,P=0.018]、摆动相最小屈曲角度[(7.62±5.28)vs(3.26±5.24)°,P=0.015]、承重反应期屈曲范围[(6.84±3.03)vs(9.75±2.89)°,P=0.005]与对照组比较仍存在统计学差异,提示伸膝功能尚未完全恢复.其余步态参数差异无统计学意义.结论 3D打印导板辅助UKA术后早期,患者步态过程中承重反应期占比、膝关节摆动相最大屈曲角度明显改善.但与对照健侧相比,步态过程中仍存在伸膝不全,主要表现为支撑相最小屈曲角度、摆动相最小屈曲角度的增大.

Objective Medial unicompartmental knee arthroplasty(UKA)is an effective knee-preserving procedure for medial compartment knee osteoarthritis.Procedures assisted by 3D-printed patient-specific instrumentation(PSI)can improve the accuracy of prosthesis positioning.However,objective quantitative evidence regarding postoperative functional recovery remains insufficient,and few studies have included comparisons with normal populations.This study aims to evaluate the early postoperative recovery pattern of sagittal knee kinematics following PSI-assisted medial UKA via 3D gait analysis,and to identify specific manifestations of postoperative gait abnormalities.Methods An observational self-controlled(affected vs contralateral limb)study design was adopted.Twenty-four patients(25 knees)who underwent 3D-printed PSI-assisted medial UKA in Department of Trauma and Joint Surgery of First Affiliated Hospital of Army Medical University between November 2024 and May 2025 were enrolled as the observation group,and 15 asymptomatic contralateral knees were selected as the control group.The hip-knee-ankle(HKA)angle,Western Ontario and McMaster Universities Osteoarthritis Index(WOMAC)score,and sagittal knee kinematic parameters were collected preoperatively and at 3 months postoperatively.Intragroup comparisons(preoperative vs postoperative data within the observation group)and intergroup comparisons(preoperative and postoperative data of the observation group vs the control group)were performed.Results The patients in the observation group were followed up for 2.90 to 6.73(4.15±1.12)months.Regarding functional scores and radiographic outcomes:postoperative WOMAC score(0.92±1.44 vs 12.76±3.94),stiffness score(0.88±1.09 vs 2.84±2.34),and function score(2.72±3.02 vs 47.80±12.08)in the observation group were significantly improved compared with preoperative values(all P<0.001).The postoperative HKA angle in the observation group was significantly larger than the preoperative value[(177.14±2.48)vs(171.44±4.21)°,P<0.001],with obvious correction of varus deformity,but there was no significant difference in the angle between the postoperative HKA angle and the control group[(177.02±3.11)°].In gait analysis:the peak knee flexion angle during swing phase was significantly increased postoperatively compared with preoperatively[(60.51±5.20)vs(47.13±12.68)°,P<0.001],and the proportion of loading response phase was decreased significantly(10.36%±3.32%vs 15.84%±11.43%,P=0.029),both recovering to the levels of the control group.However,significant differences were observed between postoperative patients and the control group in term of the minimum knee flexion angle during stance phase[(10.63±5.85)vs(6.14±5.04)°,P=0.018],minimum knee flexion angle during swing phase[(7.62±5.28)vs(3.26±5.24)°,P=0.015],and knee flexion range during loading response[(6.84±3.03)vs(9.75±2.89)°,P=0.005],which suggested that knee extension function had not been fully restored.No statistically significant differences were found in the remaining gait parameters.Conclusion In the early postoperative period after 3D-printed PSI-assisted UKA,the patients present significant improvement in the loading response phase proportion and the maximum knee flexion angle during swing phase.However,incomplete knee extension persists during gait relative to the control group,as evidenced by increased minimum knee flexion angles during both stance and swing phases.

王志鹏;黄海洪;何锐;杨鹏飞;眭文

陆军军医大学(第三军医大学)第一附属医院创伤关节外科,重庆陆军军医大学(第三军医大学)第一附属医院创伤关节外科,重庆陆军军医大学(第三军医大学)第一附属医院创伤关节外科,重庆||重庆市中医院骨伤科(关节与运动医学科),重庆陆军军医大学(第三军医大学)第一附属医院创伤关节外科,重庆陆军军医大学(第三军医大学)第一附属医院创伤关节外科,重庆

医药卫生

运动医学3D打印技术导板单髁膝关节置换术步态分析

sports medicine3D printing technologyguideunicompartmental knee arthroplastygait analysis