为了实现配电线路故障的精准定位,针对多分支配电线路在跨馈线时特征不一致和传统傅里叶行波波头提取精度差的问题,提出了一种自适应时频与能量特征融合的故障定位方法.该方法通过小波包分解,结合能量比和信息熵特征,进行跨馈线归一化,同时利用能量变化率触发自适应窗短时傅里叶变换(ST-FT),得到时频图谱和波头识别时刻.通过加权融合时间差到达算法(TDOA)与能量衰减算法(EDA),优化定位结果.通过Matlab对所提出的方法进行仿真,结果表明该定位方法在不同信噪比和接地电阻下能有效地实现故障定位,提高供电可靠性.

To achieve accurate fault location of distribution lines,a fault location method based on adaptive time-frequency and energy feature fusion was proposed,addressing the problem of inconsistent features in multi-branch distribution lines during cross-feeding and the low precision of traveling wavehead extraction in traditional Fourier methods.This method employed wavelet packet decomposition combined with energy ratio and information entropy features for cross-feed line normalization.It also utilized the energy change rate to trigger an adaptive windowed short-time Fourier transform(STFT),allowing for the acquisition of time-frequency spectrograms and the identification of wave crest moments.By weightedly integrating the time difference of arrival(TDOA)and the energy decay algorithm(EDA),the localization results were optimized.Research conducted via Matlab simulations demonstrates that the proposed localization method effectively achieves fault localization under various signal-to-noise ratios and grounding resistances,thereby enhancing supply reliability.

王志;张志刚;李舒桢;王辉;杨欣儒;赵壬福

天津市电力科技发展有限公司,天津 300409天津市电力科技发展有限公司,天津 300409天津市电力科技发展有限公司,天津 300409天津市电力科技发展有限公司,天津 300409天津理工大学 电气工程与自动化学院,天津 300384天津理工大学 电气工程与自动化学院,天津 300384

信息技术与安全科学

行波定位自适应时频特征融合时间差到达算法能量衰减算法

wave propagation positioningadaptive time-frequencyfeature fusiontime difference of arrival(TDOA)energy decay algorithm(EDA)

《电气传动》 2026 (9)

81-90,10

10.19457/j.1001-2095.dqcd27012

评论