深度调峰工况下送风机优化改造后性能试验研究OA
Experimental Study on Performance of Forced Draft Fan After Optimization and Retrofit Under Deep Peak Shaving
为了提升某 350 MW 超临界机组深度调峰工况下送风机的适应性,优化低负荷工况锅炉运行氧量调节能力,对送风机进行了降速优化改造.本文对改造后的送风机开展性能试验,结合实测数据综合评估改造效果,改造后送风机富余出力可覆盖机组全负荷运行工况,设备负载能力达标.机组各类负荷区间内,风机实际运行工况点均大幅偏离失速边界,有效避免了风机失速故障.在机组深度调峰运行条件下,锅炉风烟系统可调范围拓宽、调控灵活性显著提升,且送风机运行效率得到优化,机组厂用电消耗随之下降,有效降低辅机耗电成本,本次风机改造取得良好成效.
In order to enhance the adaptability of the forced draft fan under deep peak shaving of a certain 350 MW supercritical unit and optimize the oxygen regulation capacity of the boiler operation under low-load conditions,the forced draft fan is subjected to speed reduction and optimization transformation.It carries out relevant tests on the actual performance of the forced draft fan after its renovation,and based on the test data and results,it analyzes and studies the effect of this forced draft fan renovation.The results show that the output margin of the forced draft fan after the transformation can meet the operation requirements of the full-load section of the unit.The operating points of the fans under different loads are far from the stall line,and there is no risk of stall.The regulation capacity of the boiler flue gas system operation under deep peak shaving is enhanced.It increases the efficiency of the fan,decreases the power consumption rate of the plant,and improves the operational economy.
刘志会;赵阳
华能(大连)热电有限责任公司,辽宁 大连 116100辽宁东科电力有限公司,辽宁 沈阳 110179
能源科技
深度调峰送风机调节能力
deep peak shavingforced draft fanregulation capability
《东北电力技术》 2026 (8)
54-57,62,5