基于双模EMAT-ECT传感器与提离补偿的带涂层铝板厚度测量方法OA
A compact dual-mode EMAT-ECT sensor with lift-off compensation for thickness gauging of coated aluminum plates
电磁超声换能器(Electromagnetic acoustic transducer,EMAT)具有非接触、单面检测的优点,适用于核工业.在CAP1400围板中,涂层不均匀会引起传感器提离变化,导致EMAT信号显著衰减.传统EMAT系统无法感知提离变化,致使厚度测量结果不可靠.针对上述问题,提出一种紧凑型双模EMAT-涡流检测(Eddy current testing,ECT)复合传感器.该传感器采用单个M形磁化器和分布式激励线圈,同时产生横波与纵波,可在单次扫描中激发并独立采集两种波模式.集成的ECT通道用于估算传感器与试件之间的局部提离变化,进而对EMAT信号幅值进行补偿.仿真结果表明,偏置磁场随提离变化呈非线性衰减趋势.通过采用二次多项式拟合其衰减特性并据此建立标定曲线用于幅值补偿.仿真与实验结果表明,在0-1 mm提离范围内,ECT提离估计值的最大误差为0.038 mm;经提离补偿后,EMAT信号的波动由32%降至9%;在10 mm厚5052-H32铝合金板上,纵波与横波测厚结果分别为9.93 mm和9.96 mm,测量误差小于0.1 mm,同时两种模式下的测量结果实现了交叉验证.本研究有效解决了提离变化对核环境下带涂层安全关键结构厚度测量的干扰问题.
Electromagnetic acoustic transducers(EMATs)offer contactless,single-sided inspection for nuclear applications.In CAP1400 baffle plates,nonuniform protective coatings cause spatially varying lift-off distances that result in severe attenuation of signal amplitudes.Conventional EMAT systems cannot sense these lift-off variations,leading to unreliable thickness measurement results.To overcome this limitation,this paper presents a compact dual-mode EMAT-eddy current testing(ECT)sensor.Shear and longitudinal bulk waves are generated using a single M-shaped magnetizer and distributed excitation coils,enabling simultaneous generation and independent acquisition of both wave modes within a single scan.An integrated ECT channel estimates the local lift-off between the sensor and the specimen,and this information is used to compensate for the EMAT signal amplitude.Simulation results show a nonlinear decay of the bias magnetic field with lift-off.A quadratic polynomial is therefore utilized to fit this decay characteristic,and the resulting calibration curve is then used for compensation of the signal amplitude.The ECT channel is calibrated for lift-off estimation over 0-1 mm,with a maximum error of 0.038 mm.When this estimated lift-off is used to compensate for EMAT signals,the amplitude variation falls from 32%to 9%.Experimental validation was performed on a 10-mm-thick 5052-H32 aluminum plate.The longitudinal and shear waves returned thicknesses of 9.93 mm and 9.96 mm,respectively.These values are within 0.1 mm of the nominal thickness and are consistent with one another,offering cross-validation of the measurement.This work provides a practical solution for liftoff-tolerant thickness gauging of coated safety-critical structures in nuclear environments.
石秀丽;李强鑫;肖奇
上海开放大学宝山分校 上海宝山区业余大学,上海 200940东北大学 信息科学与工程学院,辽宁 沈阳 110004华东理工大学 机械与动力工程学院,上海 200237
电磁超声换能器双模超声检测涡流检测提离补偿铝镁合金
electromagnetic acoustic transducer(EMAT)dual-mode ultrasonic testingeddy current testing(ECT)lift-off compensationaluminum-magnesium alloy
《测试科学与仪器》 2026 (3)
468-478,11
This work was supported by the Young Scientists Fund(Category C)of the National Natural Science Foundation of China(No.12604717).