首页|期刊导航|兵工自动化|某超声速风洞主调压阀可靠性改进

某超声速风洞主调压阀可靠性改进OA

Reliability Improvement of Main Pressure Regulating Valve in Supersonic Wind Tunnel

中文摘要英文摘要

针对某超声速风洞 DN2000 主调压阀因运动部件磨损、结构振动严重,导致其运行过程中可靠性下降的问题,提出基于故障分析的阀门优化设计理念.深入分析主调压阀故障产生的根源,根据故障原因从材料、结构及生产工艺上开展优化改进设计,通过改进阀芯支撑方式、优化阀体内部结构、提升密封性能和改良位移传感器刚度等方式提高阀门的可靠性.结果表明:试验过程总压调节精度提升至±1.67%以内,新研制的调压阀结构更加安全可靠,实际使用效果良好,调压特性更加优良.

Aiming at the problem that the reliability of the DN2000 main pressure regulating valve in a supersonic wind tunnel decreases due to the wear of moving parts and serious structural vibration,the valve optimization design concept based on fault analysis is proposed.In-depth analysis of the root causes of the main pressure regulating valve failure,according to the causes of the failure from the material,structure and production process to carry out optimization and improvement design,through the improvement of the valve core support mode,optimize the internal structure of the valve body,enhance the sealing performance and improve the stiffness of the displacement sensor to improve the reliability of the valve.The results show that the total pressure regulation accuracy is improved to±1.67%during the test,the structure of the newly developed pressure regulating valve is safer and more reliable,the actual use effect is better,and the pressure regulation characteristics are more excellent.

付涌;郑晓东;余鑫

中国空气动力研究与发展中心高速所空气动力研究所,四川 绵阳 621000中国空气动力研究与发展中心高速所空气动力研究所,四川 绵阳 621000中国空气动力研究与发展中心高速所空气动力研究所,四川 绵阳 621000

航空航天

风洞主调压阀故障分析可靠性改进设计

wind tunnelmain pressure regulating valvefault analysisreliabilityimproved design

《兵工自动化》 2026 (9)

48-52,82,6

10.7690/bgzdh.2026.09.009

评论