基于惯性传感器的早期帕金森病运动功能障碍评估方法研究OA
Research on inertial sensor-based assessment method on motor dysfunction of early Par-kinson's disease
目的 基于佩戴于 3 个关键部位的惯性传感器分析早期帕金森病(PD)患者坐站转换动作与弯道行走任务的运动参数,构建早期 PD 患者运动功能障碍的客观评估方法.方法 2025-05 至 2025-12 在解放军总医院第一医学中心神经内科门诊就诊招募的 31 例受试者.采用穿戴在腰部及双侧足背的三个惯性传感器采集受试者 3 m 计时起立-行走测试的运动参数,对比分析 PD 组与对照组在坐到站体位转换及转弯行走的运动参数差异,并分析上述运动参数与对应临床评估量表评分的相关性.结果 最终纳入有效受试者 30 例,PD 组 11 例,对照组 19 例.坐站转换及弯道行走任务中,PD 组的重心左右摆幅、重心平均速度、加速度平滑度及步速均显著低于对照组,组间差异均具有统计学意义(P<0.01).PD 组坐到站的重心投影包络面积、重心平均速度与 10 m 步行测试步数呈显著负相关(r=-0.628、r=-0.803),且与高级平衡量表(FAB)评分呈显著正相关(r=0.642,r=0.725);转弯步数与 10 m 步行测试步数呈显著正相关(r=0.668),与 FAB 评分呈显著负相关(r=-0.783).结论 基于惯性传感器的重心平均速度、加速度平滑度及步速可敏感捕捉早期 PD 运动功能障碍的细微变化,为早期筛查和临床评估提供客观的数字化工具.
Objective To analyze the kinematic parameters of sit-to-stand transition and turning phase tasks in early Parkin-son's disease(PD)patients using inertial sensors worn at three key anatomical sites,and to establish an objective assessment method for motor dysfunction in early PD patients.Methods A total of 31 subjects were enrolled from the neurology outpatient department of the First Medical Center of PLA General Hospital from May 2025 to December 2025.Three inertial sensors were attached to the lumbar region and the dorsal sides of both feet to collect kinematic parameters during the 3-meter timed standing-walking test.The kinematic parameters of sit-to-stand phase and turning phase were compared between the two groups,and the correlations between these parame-ters and corresponding clinical scale scores were analyzed.Results A total of 30 effective subjects were finally included,with 11 in the PD group and 19 in the control group.During sit-to-stand phase and turning phase tasks,the PD group demonstrated significantly lower center of Mass(COM)lateral sway amplitude,mean COM velocity,acceleration smoothness,and gait speed compared with the healthy control group,and the differences between the groups were statistically significant(all P<0.01).In the PD group,the COM projection envelope area and mean COM velocity during sit-to-stand were significantly negatively correlated with the number of steps in the 10-Meter Walk Test(r=-0.628,r=-0.803),and significantly positively correlated with the Fullerton Advanced Balance Scale(FAB)score(r=0.642,r=0.725).The turn step count was significantly positively correlated with the number of steps in the 10-Me-ter Walk Test(r=0.668),and significantly negatively correlated with the FAB score(r=-0.783).Conclusions The mean COM velocity,acceleration smoothness,and gait speed based on inertial sensors can sensitively capture the subtle changes in motor dysfunction in early PD,providing an objective digital tool for early screening and clinical assessment.
张艳君;杨扬;付文倩;张洛斌;翁涌杰;蒋天裕
100853 北京,解放军总医院第二医学中心:保健一科100853 北京,解放军总医院第二医学中心:神经内科100853 北京,解放军总医院第二医学中心:保健一科310000 杭州,浙江工业大学机械工程学院310000 杭州,浙江工业大学机械工程学院100853 北京,解放军总医院第二医学中心:康复医学科
医药卫生
帕金森病惯性传感器3 m计时起立-行走体位转换弯道行走运动参数临床量表
Parkinson's diseaseinertial sensor3-meter timed standing-walkingpostural transitionturning walkingkine-matic parametersclinical scale
《武警医学》 2026 (8)
675-681,7
国家重点研发计划(2018YFC2001403)
评论