为探究脉冲电场消融(PFA)房颤过程中,距心肌表面不同深度处(0.5~4.5 mm)电场强度的分布,以及不同电压(500~2000 V)对消融区的影响,本研究基于COMSOL Multiphisics 6.1 构建了多物理场耦合的PFA 心脏模型.结果表明,消融过程中存在电场-电导率-热场的耦合影响机制,在 500 V 脉冲电压下,心肌内最高温度为 41.18℃,低于心肌热损伤阈值 50℃,心肌表面0~2.5 mm 区域内,电场强度达1000 V/cm,达到心肌不可逆电穿孔(IRE)所需的电场强度阈值400 V/cm,而深度大于3.5 mm的区域,电场强度约为 350 V/cm,无法实现有效消融;当电压由 500 增至 2000 V 时,消融深度、宽度和损伤体积分别增加 86.21%、43.37%和 412.16%.本研究探讨了脉冲电场参数对心肌的作用机制与非热主导特性,其揭示的多物理场耦合规律可为优化消融参数提供理论依据.

To investigate the distribution of electric field intensity at different depths(0.5~4.5 mm)from the myocardial surface during pulsed field ablation(PFA)for atrial fibrillation,as well as the impact of different voltages(500~2000 V)on the ablation re-gion,we established a multiphysics-coupled PFA heart model based on COMSOL Multiphysics 6.1.The results showed that there exis-ted a coupled mechanism of electric field-conductivity-temperature in the ablation process,under 500 V pulse voltage,the maxi-mum temperature within the myocardium was 41.18 ℃,always below the myocardial thermal injury threshold of 50 ℃.In the 0~2.5 mm region of the myocardial surface,the electric field intensity was as high as 1000 V/cm,reaching the threshold of 400 V/cm re-quired for irreversible electroporation(IRE)of the myocardium,whereas the region with a depth greater than 3.5 mm had an electric field intensity of approximately 350 V/cm,insufficient for effective ablation.When the voltage increased from 500 to 2000 V,the in-creased in ablation depth,width and injury volume were 86.21%,43.37%and 412.16%,respectively.This study explores the action mechanism and non-thermal dominant characteristics of pulsed electric field parameters on the myocardium,and the revealed mul-tiphysics coupling rules can provide theoretical support for optimizing ablation parameters.

赵晓玲;翁旭东;南群

北京工业大学 化学与生命科学学院,北京 100124||心肺脑复苏创新转化北京市重点实验室,北京 100124北京工业大学 化学与生命科学学院,北京 100124||心肺脑复苏创新转化北京市重点实验室,北京 100124北京工业大学 化学与生命科学学院,北京 100124||心肺脑复苏创新转化北京市重点实验室,北京 100124

医药卫生

脉冲电场消融多物理场耦合心肌组织电场电导率温度

Pulsed field ablationMultiphysics couplingMyocardial tissueElectric fieldConductivityTemperature

《生物医学工程研究》 2026 (4)

311-318,8

北京市自然科学基金项目(QY25371).