汽轮机空心静叶表面液膜蒸发特性研究OA
Study on Influence of Internal Heating on Evaporation Characteristics of Liquid Films on Turbine Stator Blade Surfaces
针对湿蒸汽汽轮机静叶表面液滴沉积后易形成液膜并诱发水蚀的问题,以某汽轮机末级静叶为研究对象,采用欧拉-拉格朗日方法对静叶通道内液滴输运、壁面成膜及内部加热条件下的液膜演化过程进行了数值研究.连续相采用shear-stress transport k-ω湍流模型(SST k-ω),液滴相采用离散相模型进行轨迹追踪,叶片外壁面设置壁膜边界以描述液滴撞壁后的液膜形成与演化过程,叶片内壁面施加冷凝换热边界以表征内部加热蒸汽对叶片壁面的热输入作用.计算结果显示:(1)内部加热对静叶通道压力场和马赫数分布影响较小,主流气动结构将基本保持一致,但其能够显著提高叶片壁面及近壁区域温度;(2)加热前后液滴在主流通道内的输运分布近似,说明内部加热的除湿作用主要在液滴撞壁后的液膜蒸发和壁面滞留的过程发生;(3)未加热工况下,液膜主要集中于叶片压力面并在计算时长内随时间持续累积;(4)内部加热后,叶片表面液膜质量高值区域明显缩小,局部最大液膜质量显著降低,t=0.009 s时,叶片表面液膜总质量由未加热工况下的约5.72×10-5 kg降低至约1.02×10-5 kg,降低了约82.2%.研究表明,内部加热可在基本不改变主流气动结构的前提下增强壁面液膜蒸发,有效抑制静叶表面液膜积聚.研究成果可为湿蒸汽汽轮机的中空静叶加热除湿设计提供参考.
Liquid film formation caused by droplet deposition on wet-steam turbine stator blades can induce water erosion.In this study,a last-stage stator blade of a steam turbine is selected as the research object,and the droplet transport,wall-film formation,and liquid-film evolution under internal heating conditions are numerically investigated using an Eulerian-Lagrangian framework.The continuous phase is solved using shear stress transport k-ω turbulence model(SST k-ω),while droplet phase is tracked using the discrete phase model.A wall-film boundary condition is applied to outer blade surface to describe liquid-film formation and evolution after droplet impingement,and a condensation heat-transfer boundary condition is imposed on inner blade surface to represent heat input from internal heating steam to blade wall.The results are as follows:(1)The internal heating has little influence on pressure field and Mach number distribution in the stator passage,and the main aerodynamic structure remains essentially unchanged.However,it significantly increases the temperatures of blade wall and near-wall region;(2)The droplet transport distributions in the main flow passage are similar before and after heating,indicating that moisture removal effect of internal heating is mainly reflected in evaporation and retention behavior of the wall film after droplet impingement;(3)Under unheated condition,the liquid film is mainly concentrated on pressure surface and continues to accumulate during the simulated period;(4)After internal heating is applied,the film regions with high mass value on blade surface are markedly reduced,and the local maximum wall-film mass decreases significantly.At t=0.009 s,the total wall-film mass on blade surface decreases from approximately 5.72×10-5 kg under unheated condition to approximately 1.02×10-5 kg under heated condition,corresponding to a reduction of about 82.2%.These results indicate that internal heating can enhance liquid-film evaporation on blade surface without substantially altering main aerodynamic structure,thereby effectively suppressing liquid-film accumulation on the stator blade surface.This study provides a reference for design of internally heated hollow stator blades for moisture removal in wet-steam turbines.
王陈寅;谢永慧;张荻;韦俊;常倩倩;封星宇
西安交通大学国家储能技术产教融合创新平台(中心),西安 710049西安交通大学国家储能技术产教融合创新平台(中心),西安 710049||西安交通大学 能源与动力工程学院,西安 710049西安交通大学 能源与动力工程学院,西安 710049中国船舶集团有限公司第七〇三研究所,哈尔滨 150078中国船舶集团有限公司第七〇三研究所,哈尔滨 150078中国船舶集团有限公司第七〇三研究所,哈尔滨 150078
能源科技
湿蒸汽汽轮机静叶内部加热离散相模型拉格朗日壁膜模型液膜演化
wet steam turbinestator bladeinternal heatingdiscrete phase modelLagrangian wall film modelliquid film evolution
《热力透平》 2026 (3)
184-192,9
评论