首页|期刊导航|LabMed Discovery|Toward standardized antithrombin activity assays:multi-center evaluation and optimization

Toward standardized antithrombin activity assays:multi-center evaluation and optimizationOA

中文摘要

Objectives Antithrombin(AT)is a critical anticoagulant whose deficiency,which is common in many clinical conditions,requires precise management.However,accurate laboratory measurements of low AT levels are challenging.This study aims to evaluate the precision and comparability of AT activity assays across different analytical systems,particularly at low activity levels,with the goal of developing validated optimization strategies to improve performance and interlaboratory harmonization.Methods Standardized lyophilized plasma materials(with AT activities of 10%,15%,35%,and 100%of normal)were distributed to nine clinical laboratories via Systems A and B,with bovine thrombin as the reagent,and System C,with bovine activated coagulation factorⅩas the reagent.Baseline performance was assessed through a laboratory evaluation and external quality assessment style comparison.Optimization measures(standardized reagent reconstitution,calibration curves at low levels,enhanced quality control protocols)were then applied in laboratories with better baseline performance,followed by a re-evaluation study to assess improvements.Results The initial evaluation confirmed significant variability at low AT activity levels:Systems A and B demonstrated closer agreement with target levels,whereas System C exhibited significant bias and poor reproducibility and was consequently excluded from optimization.After implementation of the optimization protocols,low-level AT activity measurements showed markedly reduced bias and improved precision.At the 10%and 15%levels,both the interlaboratory coefficients of variation and the recovery rates significantly improved.In the re-evaluation study,Systems A and B demonstrated enhanced performance across all participating laboratories.Conclusions This multi-center evaluation established the feasibility of significantly improving AT activity assay performance through targeted methodological optimization.Through the use of quality control materials and harmonized procedures,the method achieved reliable low-level activity measurements,thereby paving the way for reliable clinical application of AT activity measurements.

Yu Liu;Ying Song;Yu-Hua Wang;Zhen-Ping Chen;Qiang Li;Run-Hui Wu;Jing Sun;Lei Zhang;Xiao-Bo Hu;Ren-Chi Yang;Xue-Feng Wang;Jing Dai

Department of Laboratory Medicine,Ruijin Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200025,ChinaDepartment of Clinical Hematology and Osteology,Shanghai Center for Clinical Laboratory,Shanghai 200126,ChinaState Key Laboratory of Experimental Hematology,National Clinical Research Center for Blood Diseases,Haihe Laboratory of Cell Ecosystem,Institute of Hematology&Blood Diseases Hospital,Chinese Academy of Medical Sciences&Peking Union Medical College,Tianjin 300020,ChinaDepartment of Clinical Laboratory Center,Beijing Children’s Hospital,Capital Medical University,National Center for Children’s Health,Beijing 100045,ChinaDepartment of Laboratory Medicine,Nanfang Hospital,Southern Medical University,Guangzhou 510515,ChinaDepartment of Hematology,Beijing Children’s Hospital,Capital Medical University,National Center for Children’s Health,Beijing 100045,ChinaDepartment of Hematology,Nanfang Hospital,Southern Medical University,Guangzhou 510515,ChinaState Key Laboratory of Experimental Hematology,National Clinical Research Center for Blood Diseases,Haihe Laboratory of Cell Ecosystem,Institute of Hematology&Blood Diseases Hospital,Chinese Academy of Medical Sciences&Peking Union Medical College,Tianjin 300020,ChinaShanghai Center for Clinical Laboratory,Shanghai 200126,ChinaState Key Laboratory of Experimental Hematology,National Clinical Research Center for Blood Diseases,Haihe Laboratory of Cell Ecosystem,Institute of Hematology&Blood Diseases Hospital,Chinese Academy of Medical Sciences&Peking Union Medical College,Tianjin 300020,ChinaDepartment of Laboratory Medicine,Ruijin Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200025,ChinaDepartment of Laboratory Medicine,Ruijin Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200025,China

医药卫生

Antithrombin(AT)Standardized testingLow-level activity measurementExternal quality assessment(EQA)

《LabMed Discovery》 2026 (1)

P.1-9,9

supported by the National Natural Science Foundation of China(No.82470131)the Research Physician Innovation and Transformation Competence Training Program of Shanghai Shenkang Hospital Development Center,China(No.SHDC2023CRD004).

10.1016/j.lmd.2026.100117

评论